background image

PUMP OPERATION:

High performance can be obtained from these pumps if the engine speed is 
increased, however, we do not recommend the pumps be operated over 3600rpm 
for extended periods, as this may overload the engine and reduce its working life. 
Operating the engine at full throttle for extended periods will shorten engine life 
and may result in premature failure. For operations such as water transfer and 
tank filling, the throttle should be closed to around 3/4 maximum. This should 
correspond to around 3000rpm maximum.

AvOIDINg PUMP DAMAgE:

Pumping water containing chemicals or high concentrations of salt may damage 
pump components. If the pump is used for this kind of service, life will be 
extended by always washing thoroughly with clean water after use. However, 
Davey cannot accept responsibility for damage caused by chemicals, salt or 
corrosive fluids.

Pumping hydrocarbon based liquids, even in diluted form, is likely to cause 
damage to internal pump components and such failure is not covered by 
guarantee.

ENgINE OIL

The use of good quality, correctly rated engine oil is very important to the long 
term dependability of your engine, especially when you need it most. Check the 
manufacturer’s recommendations for the correct grade of oil and stick to their 
recommendations. Do not use a synthetic, multigrade motor vehicle oil in your 
small engine, it simply is the wrong oil for this type of engine.

Diesel engines require specific oils designed for diesel, and the diesel engine on 
your pump will need a different oil to that used for truck or motor vehicle engines.

Honda and Hatz offer their own branded specialty oils to suit their engines best, 
but no matter who makes the oil, use the right grades and stick to trusted brands.

Davey include a label with every engine to advise of the correct oil to use, which are:

•  Honda Petrol Engines: SAE 10W-30 mineral oil.  For extreme conditions 

alternate oil grade may be appropriate – check manual.

•  Hatz B Series Diesel Engines: MONOGRADE SAE30, API CD lubricating oil 

for an ambient temperature in the range from 0°C to 35°C.  Use monograde 
SAE40 for ambient temperatures up to 45°C.

Running the engine regularly will help ensure the oil is distributed around the 
engine, thus providing the best lubrication and longer engine life.

4

Содержание jumbo floodfighter

Страница 1: ...s Installation and Operating Instructions These Instructions and the accompanying engine manufacturer s instructions must be delivered with the pump to the operator Please pass these instructions on to the operator of this equipment ...

Страница 2: ...l protection Check oil levels and maintain oil quality regularly IMPORTANT NOTICE The Honda engine fitted to the Davey Floodfighter has an automatic oil level cut out which will stop the engine and or prevent starting when oil level is low and or when engine is tilted In emergency circumstances only oil level cut out may be disabled as follows FOR HONDA Disconnect yellow lead to starting switch at...

Страница 3: ...ere air may be trapped All pipe connections must be air tight for best priming and pump operation check that washers in nuts and tails are in good order DISCHARGE PIPE Care should be taken with the selection of pipe pressure rating as the 3 Jumbo Floodfighter is capable of delivering pressures of 250kPa PUMP PRIMING To prime the pump initially it is necessary to fill the pump body with water befor...

Страница 4: ...f good quality correctly rated engine oil is very important to the long term dependability of your engine especially when you need it most Check the manufacturer s recommendations for the correct grade of oil and stick to their recommendations Do not use a synthetic multigrade motor vehicle oil in your small engine it simply is the wrong oil for this type of engine Diesel engines require specific ...

Страница 5: ...ines are often not treated as well as they deserve oil changes are the most common item neglected STORAGE OF UNIT The pump unit should be drained of water and normal engine storage procedure should be followed Run unit until fuel is exhausted drain and fill sump with fresh oil The unit should be stored in a dry place Before starting pump after storage it should be checked to make sure that it is f...

Страница 6: ... _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________...

Страница 7: ... _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________...

Страница 8: ...product was not designed or advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive water or other liquid lightning or high voltage spikes or unauthorized persons attempting repairs Where applicable your Davey product must only be connected to the voltage shown on the nameplate Your Davey Guarantee does not c...

Отзывы: