Engine:
Fill sump with oil to correct level before starting the four stroke engine.
Operation at high altitudes, high temperatures and/or humidity will
reduce engine performance.
NOTE:
• Your Davey pump is fitted with a four stroke engine WHICH
REQUIRES OIL IN THE SUMP.
• Petrol engines require UNLEADED petrol in the fuel tank.
• Read ALL instructions to avoid equipment failure which may
not be covered by guarantee.
• Fill sump with oil and pump with water before starting. HATZ
diesel engines do not have low oil protection. Check oil levels
and maintain oil quality regularly.
IMPORTANT NOTICE:
The Honda engine fitted to the Davey Floodfighter
™
has an
automatic oil level cut-out which will stop the engine and/or
prevent starting when oil level is low and/or when engine is tilted.
IN EMERgENCY CIRCUMSTANCES ONLY, OIL LEvEL CUT-OUT MAY bE
DISAbLED AS FOLLOWS:
FOR HONDA:
Disconnect yellow lead to starting switch at ‘bullet’ junction.
NOTE: WARRANTY FROM THE ENgINE MANUFACTURERS MAY bE
JEOPARDISED bY SUCH ACTIONS.
READ ALL INSTRUCTIONS
bEFORE OPERATINg PUMP
WARNINg:
Engine manufacturer’s instructions must be followed to ensure
safe operation of this product and to avoid possible engine
damage or reduced engine life.
2