10
5. ENGINE WARNINGS
IMPORTANT: The Firefighter pump
is fitted with a quality engine which
requires oil in the sump. Read ALL
instructions to avoid equipment
failure which may not be covered
by guarantee.
• Fill sump with oil and Firefighter pump with water
before starting;
• Check oil levels and maintain oil quality regularly;
• Operation at high altitudes, high temperatures
and/or humidity, will reduce engine performance;
• Engine manufacturer’s instructions must be
followed to ensure safe operation of the Firefighter
pump and to void possible engine damage, or
reduced engine life;
• We are obliged to inform you that the Firefighter
pump is not to be used by children, or infirm
persons and must not be used as a toy by
children;
• In certain conditions or operation, the sound level
of some models of Firefighter pump can exceed
85dB(a) at 1metre.
ATTENTION: Exhaust from this
engine is both poisonous and hot.
Ensure the exhaust is directed
away from people, animals and any
flammable materials.
5.1 Petrol engines
• Fill sump with oil to correct level before starting
the four-stroke engine;
• Petrol engines require unleaded petrol in the
fuel tank.
The Honda engines fitted to Firefighter pumps have
an automatic oil level cut-out which will stop the
engine and/or prevent starting when oil level is low
and/or when engine is tilted.
IN EMERGENCY CIRCUMSTANCES
ONLY, OIL LEVEL CUT-OUT MAY BE
DISABLED AS FOLLOWS:
• Disconnect yellow lead to starting
switch at “bullet” junction.
IMPORTANT: WARRANTY FROM THE
ENGINE MANUFACTURER MAY BE
JEOPARDISED BY SUCH ACTIONS.
5.2 Diesel engines
Yanmar diesel engines do not have low oil protection.
6. BE PREPARED
Your Firefighter pump and pipework is an important
part of fire protection, but so are the other things
you must do to be ready. Davey recommends you
work through your fire plan and make sure it’s able
to work under a realistic assessment of the worst
possible situation. Fire only really understands the
worst possible situation. Here’s a checklist for your
Firefighter pump and equipment.
6.1 Practice
Make sure you and all your team are competent in
the use of the equipment:
Can they start and correctly operate your Firefighter
pump?
• Can they operate the hoses correctly?
• Do they have a clear understanding of risks and
what to do to ensure safety?
• Can each person in your team operate alone, or
do you have a plan for single and multiple team
members?
Run drills. Practice and make sure everyone
understands the fire plan and their part in that plan.
7. REMOTE START FIREFIGHTER
MODELS
Your system’s mobile phone number:
WARNING: Keep secure!
(Applicable to Davey remote start Firefighter models only.)
Remote/Auto
Control Centre
Priming Port
Drain Port
3 Way Outlet
Figure 7.1
Engine Exhaust*
Battery
(not included)
SMS aerial
Key Start
Recoil Start
Figure 7.2
Prior to use the pump requires correct preparation: