background image

!

%!

 

 

 

Salt Water Pool System

 

Congratulations!  You  are  now  the  proud  owner  of  the  renowned  EcoSalt

 

REDOX  Salt  Water 

Chlorinator.  Please  read  all  information  in  this  manual  carefully  before  installing  or  operating  your 
EcoSalt

 

REDOX

 

Salt Water Pool Chlorinator

.

 

 

Table of contents

 

 

 

Page 4

 

Page 5

 

Page 6-7

 

Page 8

 

Page 8-9

 

Page 10

 

Page 11-12

 

Page 13-14

 

Page 14

 

Page 15

 

Page 16

 

Page 17

 

Page 20

 

Packing List 
Important Notice

 

Installation Instructions 
Pre-Start Up Procedure

 

Setting and Operating Your EcoSalt REDOX System   

EcoSalt

 

REDOX Special

 Features 

 

EcoSalt REDOX System Maintenance   
Day to Day Operation

 

Chlorine Production

 

General Information: Recommended Pool Water Chemistry 
Trouble Shooting

 

Mounting Details

 

Davey Contact Information

 

 

Packing List

 

 

Included with your EcoSalt

 

REDOX 

System are the following items, please check the contents of the box 

carefully prior to attempting to install the system:

 

 

1. 

Power Supply / Controller

 

2. 

In-Line Electrolytic Cell

 

3. 

ORP Probe

 

4. 

2 x 50mm Barrel Unions

 

5. 

2 x Pipe Adaptors 63/50mm to 61/50mm

 

6. 

Threaded Reducer 25/20mm

 

7. 

Mounting Kit & Spare Fuse

 

8. 

Flow Switch & Saddle Clamp

 

9. 

Manifold for ORP Probe 

 

10. 

Earth Bolt & Saddle Clamp

 

11. 

Installation & Operating Instructions

 

Содержание EcoSalt MC12ORP

Страница 1: ...Salt Water Pool System Model MC12ORP Installation Operating Instructions Please pass these instructions on to the operator of this equipment...

Страница 2: ......

Страница 3: ...children without supervision Power connections and wiring must be carried out by an authorised electrician Before making any electrical connections ensure power to the appliance is disconnected IMPORT...

Страница 4: ...DOX System EcoSalt REDOX Special Features EcoSalt REDOX System Maintenance Day to Day Operation Chlorine Production General Information Recommended Pool Water Chemistry Trouble Shooting Mounting Detai...

Страница 5: ...electrolytic In Line cell is recommended The Cell is the transparent plastic housing containing the electrode plates During the chlorination process a white powdery Calcium scale may naturally build...

Страница 6: ...it screws provided Once screws are in position simply hang chlorinator via mounting slots at the rear of the top panel Note the additional mounting slot at the base can be used to help secure the unit...

Страница 7: ...ER SUPPLY The EcoSalt REDOX is supplied with a Manifold for installation of the Flow Switch and ORP Probe The Manifold MUST be installed after the Filter and at least 200mm prior to the Cell inlet as...

Страница 8: ...NTROL PANEL LAYOUT 1 To set your EcoSalt REDOX first ensure the pH 7 2 7 6 and Total Alkalinity 80 150ppm are balanced then add chlorine whilst the unit is running to reach your desired level of chlor...

Страница 9: ...D SALT Indicator 9 What is ORP EcoSalt REDOX uses an ORP Probe to determine whether or not chlorine needs to be produced to sanitise the pool ORP levels are measured in millivolts mV The ORP Probe doe...

Страница 10: ...ol The salt level is also reduced by rain which causes dilution Salt is not lost to evaporation There are other factors that can cause an Add Salt indication 1 Heavy Rain can cause very dilute pool wa...

Страница 11: ...been chlorinated with calcium hypochlorite for an extended period Calcium in the plaster surfaces of a concrete pool Because these conditions vary so much check the Cell at least weekly to begin with...

Страница 12: ...work and re connect SAFETY DEVICE Hydrogen Gas is a by product of the chlorine producing process A Flow Switch has been supplied with the unit which will switch off chlorine production if low or no f...

Страница 13: ...inity can cause unstable pH levels i e an inability to keep the pH constant may cause staining etching and corrosion of metals High Total Alkalinity will cause constantly high pH levels IMPORTANT For...

Страница 14: ...r and chlorinator for the suggested times and ORP levels and test your pool water on the morning after operation If your chlorine test shows a high level of chlorine the ORP CONTROL can be turned anti...

Страница 15: ...e are numerous varieties some are free floating whilst others grow on walls and in cracks and come in different colours Some are more resistant to chemical treatment than others Bacteria The germs tha...

Страница 16: ...outlet switched off circuit breaker tripped 2 Chlorinator not connected correctly into main outlet 3 ORP CONTROL turned to minimum setting 4 Chlorinator fuse blown 5 Dirty or failed Cell 6 Filter nee...

Страница 17: ...Mounting Details 50mm...

Страница 18: ...Notes...

Страница 19: ...Notes...

Страница 20: ...Installation and operating instructions are included with the product when purchased new They may also be found on our website...

Отзывы: