Day to Day Operation

 

 

Four Prime rules must be observed if your unit is to give the best possible service: 
 

4. 

STABILISER

 

The importance of pool stabiliser in 

outdoor

 pools cannot be over-emphasised.  It is essential in helping 

retain chlorine in your  pool. Chlorine is rapidly dissipated by sunlight and the use of stabiliser will reduce this 
dissipation substantially.  Without stabiliser, it may be necessary to run the Unit for up to three times as long!

 

water. Stabiliser should be  maintained at a level of 15 to 20 ppm. Before adding more stabiliser, have your 
pool water analysed at your pool  shop to ensure that you do not add too much. Stabiliser is NOT 
recommended for indoor pools. 

 

5. 

pH AND TOTAL ALKALINITY:

 

A correct pH level must be maintained to prevent problems such as black spot, staining, cloudy water, etc.  
An  incorrect pH level can damage the pool. Correct pH levels are as follows; Fibreglass Ð 7.2 to 7.4 Concrete 
& tiled

 

Р7.4 to 7.6. If you allow the pH level to rise to 8.0 or above, the chlorine required could be as much as 

three times  the normal amount.

 

 

Total Alkalinity should not be confused with pH, although the two are closely related. Total Alkalinity 
determines  the speed and ease of pH change. The ideal range is 80 to 150 ppm, or refer to your pool 
professional. 

 

You should use a test kit which includes a test for Total Alkalinity. Low Total Alkalinity can cause unstable pH 
levels Ð i.e. an inability to keep the pH constant may cause staining, etching and corrosion of metals. High 
Total  Alkalinity will cause constantly high pH levels. 
 

IMPORTANT: For the ORP control to function correctly, pH and Total Alkalinity MUST be maintained 
at the correct levels. 

 

6. 

SALT LEVELS:

 

 

 
Salt is the essential element by which your Unit operates. Not enough salt means not enough chlorine Ð this 
simple rule governs the total operation of your 

EcoSaltª REDOX, and

 insufficient salt will damage your Cell.

 

 

RECOMMENDED SALT LEVEL RANGE:  

4500 - 6000ppm

 

 

 

Salt is NOT used up in the process of producing chlorine or by evaporation. Salt is only lost through 
backwashing, splash-out, 

overflow or by leakage from the pool or plumbing. Heavy rain can dilute the salt 

solution in  your pool; therefore salt levels should be checked during this season. 
 

Low salt levels will destroy the coating on the Anode plates and will void all Warranty.

 

The EcoSalt REDOX has a built in warning indicator to minimise damage resulting from insufficient salt 
levels, however, the ultimate responsibility is on the owner to ensure adequate salt levels are maintained all 
year round. 
 

Warning:  Some people recommend that you put salt directly in the skimmer box. This is a 
very  poor  practice as it allows very high concentrations of salt to be passed through your 
filtration and other pool equipment.

 

Warning:

 

Do not add Hydrogen Peroxide to pool water or through swimming pool hydraulic or 
sanitiser system. Use of Hydrogen Peroxide will void warranty on Davey products.

 

Содержание EcoSalt MC12ORP

Страница 1: ...Salt Water Pool System Model MC12ORP Installation Operating Instructions Please pass these instructions on to the operator of this equipment...

Страница 2: ......

Страница 3: ...children without supervision Power connections and wiring must be carried out by an authorised electrician Before making any electrical connections ensure power to the appliance is disconnected IMPORT...

Страница 4: ...DOX System EcoSalt REDOX Special Features EcoSalt REDOX System Maintenance Day to Day Operation Chlorine Production General Information Recommended Pool Water Chemistry Trouble Shooting Mounting Detai...

Страница 5: ...electrolytic In Line cell is recommended The Cell is the transparent plastic housing containing the electrode plates During the chlorination process a white powdery Calcium scale may naturally build...

Страница 6: ...it screws provided Once screws are in position simply hang chlorinator via mounting slots at the rear of the top panel Note the additional mounting slot at the base can be used to help secure the unit...

Страница 7: ...ER SUPPLY The EcoSalt REDOX is supplied with a Manifold for installation of the Flow Switch and ORP Probe The Manifold MUST be installed after the Filter and at least 200mm prior to the Cell inlet as...

Страница 8: ...NTROL PANEL LAYOUT 1 To set your EcoSalt REDOX first ensure the pH 7 2 7 6 and Total Alkalinity 80 150ppm are balanced then add chlorine whilst the unit is running to reach your desired level of chlor...

Страница 9: ...D SALT Indicator 9 What is ORP EcoSalt REDOX uses an ORP Probe to determine whether or not chlorine needs to be produced to sanitise the pool ORP levels are measured in millivolts mV The ORP Probe doe...

Страница 10: ...ol The salt level is also reduced by rain which causes dilution Salt is not lost to evaporation There are other factors that can cause an Add Salt indication 1 Heavy Rain can cause very dilute pool wa...

Страница 11: ...been chlorinated with calcium hypochlorite for an extended period Calcium in the plaster surfaces of a concrete pool Because these conditions vary so much check the Cell at least weekly to begin with...

Страница 12: ...work and re connect SAFETY DEVICE Hydrogen Gas is a by product of the chlorine producing process A Flow Switch has been supplied with the unit which will switch off chlorine production if low or no f...

Страница 13: ...inity can cause unstable pH levels i e an inability to keep the pH constant may cause staining etching and corrosion of metals High Total Alkalinity will cause constantly high pH levels IMPORTANT For...

Страница 14: ...r and chlorinator for the suggested times and ORP levels and test your pool water on the morning after operation If your chlorine test shows a high level of chlorine the ORP CONTROL can be turned anti...

Страница 15: ...e are numerous varieties some are free floating whilst others grow on walls and in cracks and come in different colours Some are more resistant to chemical treatment than others Bacteria The germs tha...

Страница 16: ...outlet switched off circuit breaker tripped 2 Chlorinator not connected correctly into main outlet 3 ORP CONTROL turned to minimum setting 4 Chlorinator fuse blown 5 Dirty or failed Cell 6 Filter nee...

Страница 17: ...Mounting Details 50mm...

Страница 18: ...Notes...

Страница 19: ...Notes...

Страница 20: ...Installation and operating instructions are included with the product when purchased new They may also be found on our website...

Отзывы: