background image

11

e. Wi-Fi 

When the screen is on, press 

 for 3 seconds, after   flashing, enter Wi-Fi connection. Connect Wi-Fi 

on mobile phone and input password, and then control equipment via Wi-Fi. When APP connects Wi-Fi 

successfully   lights on.

f. Defrosting

1)  Automatic defrosting: When machine is auto defrosting, 

 will flash, and return to previous working 

mode when it finishes.

2)  Manual Defrosting: To enter forced defrosting mode, the compressor must be on for more than 10 

minutes. In heating mode, hold 

 and 

 on touch controller simultaneously for 5 seconds to start 

forced defrosting, 

 is flashing and defrost starts, 

 stop flashing and defrosting stops.

(Remarks: the interval between manual defrosting should be more than 30 minutes).

g. Heat Pump Status Checking

Make sure the heat pump is running.

Press 

 for 5 seconds until you hear a beep, it will enter into running status check, the display

alternately shows the status point C0 and its corresponding value.
Use up and down arrows to show the other values.

Press 

 to exit status check mode.

SYMBOL

CONTENT

UNIT

C0

Inlet water temp

°C

C1

Outlet water temp

°C

C2

Ambient temp

°C

C3

Exhaust temp

°C

C4

Outer coil pipe temp

°C

C5

Gas return temp

°C

C6

Inner coil pipe temp

°C

C9

Radiator temp

°C

C10

Electronic expansion valve opening

P

C11

DC fan speed

r/min

6. TESTING

6.1 Inspect heat pump before use

a. Ensure the ventilation is adequate and there are no obstructions.
b. Ensure your Davey heat pump is not close to any corrosive substances.
c. Verify that the electrical wiring has been completed as per instructions.

6.2 Leakage detection notice and method

a. Keep away from any sources of ignition. A halide torch 

(or any other detector using a naked flame) shall not be used.

b. Leakage detection fluids can be applied with most refrigerants but the use of detergents containing 

chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe.

c. If a gas leak occurs, cease operation and contact a Davey service centre.

6.3 Trial

a. Your water circulation pump must be running before your Davey heat pump starts and needs to continue 

running until after your heat pump stops. This will avoid damage to your heat pump.

R32 Gas

Содержание DHP130

Страница 1: ...Please pass on these instructions to the operator of this equipment Pool Heat Pump Installation and Operating Instructions...

Страница 2: ...ANCE 7 4 1 Installation reminder 7 4 2 Wiring 9 4 3 Electric wiring diagram 9 4 4 References for protecting devices and cable specification 9 5 OPERATION GUIDANCE 10 5 1 Key function 10 5 2 Operation...

Страница 3: ...appliance or an operating electric heater Do not pierce or burn Be aware that refrigerants may not contain an odour R32 Gas INSTALLATION REMINDERS The installation of any pipework should be kept to a...

Страница 4: ...r outage happens during operation the heat pump will start when the power is restored c Please switch off the main power supply in lightening and storm weather to prevent from damage caused by lightni...

Страница 5: ...ortant to ensure that the flow rate in set to the advised water flow rate in section 3 6 and that the pressure does not exceed 500kPa In accordance with AS NZS 60335 2 40 we are obligated to inform yo...

Страница 6: ...0 19 1 38 0 26 1 80 0 33 2 50 0 38 2 90 0 49 3 80 0 65 4 84 Input power at 50 speed kW 0 51 0 7 0 95 1 1 1 44 1 84 Rated input current A 0 83 5 98 1 13 7 83 1 44 10 90 1 66 12 7 2 15 16 53 0 95 7 01...

Страница 7: ...his heat through its heat exchanger to the pool water Your Davey heat pump should be installed in a well ventilated area WARNING Improper installation adjustment service maintenance or use can cause f...

Страница 8: ...fastened the bracket must be strong enough and antirust treated 2 Please ensure 50cm of clearance around each side of the Davey heat pump or the efficiency of the heat pump will be reduced 3 Although...

Страница 9: ...full disconnection of the power supply must be incorporated in the fixed wiring in accordance with the wiring rules 4 3 Electric wiring diagram a For power supply 230V 50Hz Distribution Box Power Sup...

Страница 10: ...ark when it s locked 5 2 Operation Instruction a Screen Lock 1 Press for 3 seconds to lock or unlock the screen 2 Automatic Lock Period 30 seconds if no operation b Power On Press for 3 seconds to unl...

Страница 11: ...ss to exit status check mode SYMBOL CONTENT UNIT C0 Inlet water temp C C1 Outlet water temp C C2 Ambient temp C C3 Exhaust temp C C4 Outer coil pipe temp C C5 Gas return temp C C6 Inner coil pipe temp...

Страница 12: ...to occur to the Davey heat pump a Turn off the circuit breaker or isolation switch b Drain the Davey heat pump Loosen all water connections c Rinse the interior of the heat exchanger cylinder with a...

Страница 13: ...avoided The area around the workspace should be sectioned off Ensure that all conditions within the area have been made safe by control of flammable material 3 Always check the work area with an appr...

Страница 14: ...chlorine may react with the refrigerant and corrode the copper pipework If a leak is suspected all naked flames should be removed or extinguished If a leakage of refrigerant is found which requires b...

Страница 15: ...outlet water Insufficient water flow protection 4 Eb Ambient temperature too high or too low protection 5 Ed Anti freezing reminder No Display Failure Code Description 1 E1 High pressure protection 2...

Страница 16: ...mperature difference then either restart the heat pump or go back into standby The default setting is P2 To change these parameters please contact your nearest Davey dealer verter heat pump solution I...

Страница 17: ...V 50Hz Customer prepare Power Supply 230V 50Hz Earthing Water pump 230V voltage 500W capacity Breaker fuse Customer prepare Breaker fuse Customer prepare Contactor Powercord 17 Customer remote control...

Страница 18: ...18...

Страница 19: ...nt Registration Register by e mail or third party application Android iOS a E mail registration Android please download from iPhone please download from 1 APP Download 2 Account registration 1 Registe...

Страница 20: ...20 Please set family name and choose location of device Create Family b Register through third party application...

Страница 21: ...21 APP Pairing a With Bluetooth 1 Please confirm that you re connected to Wi Fi and your Bluetooth is on 2 Click Add Device and then follow the instructions to pair device...

Страница 22: ...d release After hearing Beep enter Wi Fi password in app During connection will flash Once the app connects to Wi Fi successfully will display b With Wi Fi 1 Please make sure you are connected to Wi F...

Страница 23: ...r On Off Setting temperature Select Boost Silence Mode 2 For heat pump with Heating Cooling function Compressor speed Query C F switch Setting temperature Select Boost Silence Mode Compressor speed In...

Страница 24: ...ather forecast is just for reference 2 App is subject to updates without notice After pairing if your family members also want to control the device please let your family members register InverGo fir...

Страница 25: ...tor DHP3503 1 14 403771 Sensors full set 1 16 16294 R32 Compressor DHP130 1 16 16296 R32 Compressor DHP170 210 1 16 16304 R32 Compressor DHP280 1 16 16305 R32 Compressor DHP3503 1 16 16292 R32 Compres...

Страница 26: ...26 NOTES...

Страница 27: ...27...

Страница 28: ...their product knowledge and reasonable judgement and will be accepted if a relevant defect is found the warranty claim is made during the relevant warranty period and none of the excluded conditions...

Отзывы: