Replacing the UV lamp – Yearly

Carefully unwrap the replacement lamp. The packaging can be reused to return your 
old lamp to your place of purchase for recycling. Do not break the old lamp and do 
not dispose of it in general waste. 

–  Disconnect power by unplugging the cord set.

–  Depressurise the system and drain the UV chamber by removing the drain plug. 

Remember to put the plug back on when the chamber is empty.

–  Turn off water supply to the inlet of the Steriflo.

–  Unscrew the earth connection

–  Unscrew the 2 small screws holding the endcap on.

–  This will expose the wiring for the lamp. Disconnect the lamp and remove it 

straight up. Only handle the lamp by the ceramic-coated ends. 

–  Insert the new lamp and reconnect the wiring. Push the cords into the top of the 

quartz sleeve so that the 2 small screws can be inserted.

–  Connect the earth wire.

–  Plug in the power and turn on. Allow the lamp to run for 2 minutes, turn the water on.

–  Ensure the reset button is pressed and held for approx. 10 seconds. The unit should 

beep to indicate the lamp life timer has been reset. The timer will then count down 
for 12 months and beep alarm when the lamp needs to be replaced.

–  Securely wrap the used lamp in the packaging and return it to your place of 

purchase for return to Davey Water Products and recycling.

–  If alarm sounds, turn power off for 5 minutes to allow internal reset of the power supply.

Sediment Cartridge Filter Life

Once the housing is properly installed, a reduction in flow/pressure (to such an extent 
as to cause inconvenience) will indicate when the cartridge is becoming clogged and 
needs replacing or cleaning. Sediment cartridges should be replaced or cleaned and 
sanitised when the water flow has been noticeably reduced or after 3-6 months – 
whichever comes first (this is for hygiene reasons).

NOTE:  Actual filtration/purification life of cartridge can vary with the condition 

of incoming water.

NOTE:  It is possible to wash the 20 micron pleated cartridge with mild 

detergent. Once damage is evident it should be replaced. The one 
micron polyspun cartridge is NOT WASHABLE and should be replaced 
for hygiene reasons every 6 - 12 months.

Содержание aquashield centurion ASC50

Страница 1: ...ning will expose persons to the possibility of personal injury and may result in damage to the UV system or other property This unit is designed to treat water at ambient temperatures 5 C to 45 C Cont...

Страница 2: ...Power Surge Protection 4 Power Connection 4 Mounting Plumbing and Start Up 5 LED Indicators 6 Alarms 6 Maintenance 7 Cleaning the quartz sleeve 7 Changing the Filter Cartridge 8 Replacing the UV lamp...

Страница 3: ...alarm beeps on and off the lamp is due to be changed so that effective treatment is maintained Flashing of the red LED indicates that the lamp countdown timer is operating Recommendations for maintai...

Страница 4: ...from leaking pipe joints or seals Electrical Power Surge Protection An electrical power surge or spike can travel on the supply lines and cause serious damage to your electrical equipment The Steriflo...

Страница 5: ...lamp The lamp is shipped in a tube in the top of the box Carefully unwrap the lamp and slide it into the pre fitted quartz sleeve through the top of the endcap Connect the lamp connection plugs and p...

Страница 6: ...ashing of the red LED indicates normal operation and the lamp countdown timer is operating Should the unit alarm power to the pump will be interrupted ensuring safe water is always supplied Manual ove...

Страница 7: ...endcap from the sleeve Lift the quartz sleeve out of the chamber by pulling it straight up Try to handle the quartz sleeve by holding it by the top 2cm Try not to handle the quartz sleeve as fingerpr...

Страница 8: ...eaks 5 Screw the housing onto the lid and hand tighten Open the tap downstream of the filter and then open the inlet valve The cartridge spanner supplied with the unit may help if the housing is tight...

Страница 9: ...ld for approx 10 seconds The unit should beep to indicate the lamp life timer has been reset The timer will then count down for 12 months and beep alarm when the lamp needs to be replaced Securely wra...

Страница 10: ...xposure skin sloughing peeling weeping area sever sunburn symptoms FIRST AID EYES In mild cases if in doubt seek medical attention Severe cases cover eyes with gauze or clean cloth seek medical attent...

Страница 11: ...11...

Страница 12: ...ors loss or damage resulting from misuse or negligent handling improper use for which the product was not designed or advertised failure to properly follow the provided installation and operating inst...

Отзывы: