Changing the Filter Cartridge

1. Turn off the water flow to the cartridges at the valve, tank or tap.
2. Release the pressure by opening a tap downstream, or use the pressure relief 

valve that is available in the lid of the filter housings.

3. Unscrew the bottom housing from the lid* and remove the used cartridge and 

discard or wash. The inside of the filter housing and the lid should be checked for 
cleanliness – they will usually need to be cleaned or sanitised – use hot water and 
dishwashing liquid, thoroughly scrub all surfaces and then rinse.

4. Check that the o-ring is in position in the top of the housing base, lubricate with 

a coating of suitable rubber lubricant, such as silicone. Place the o-ring into the 
groove and with two fingers wipe the o-ring down into the groove. Do not wipe the 
o-ring clean of lubricant after it has been properly seated in the groove because 
the lubricant prevents “crawling” of the o-ring during the tightening of the lid and 
thus prevents water leaks.

5. Screw the housing onto the lid and hand tighten. Open the tap downstream of the 

filter and then open the inlet valve.

*The cartridge spanner supplied with the unit may help if the housing is tight.

CAUTION: The housing must be protected against freezing. Failure to do so 
may result in cracking of the housing and water leakage.

WARNING: CAREFULLY AND GENTLY TIGHTEN WITH HOUSING SPANNER 
as the bowl should only be tightened enough to avoid water leaking during 
operation.

WARNING: If the water system is not going to be used for extended periods, 
the cartridge should be removed from the housing and replaced with a new or 
cleaned cartridge when the system is used again.

IMPORTANT: When opening the filter housing to install or change the 
cartridge (element) it is common for the o-ring seal to lift out of the groove 
and, at times, it may even stick to the cap.

CAUTION WHEN INSTALLING
1. This is a plastic product with a female thread. If you cross-thread a male 

fitting, and/or you over pack with sealing tape, you could do permanent 
damage.

2. If you use a tapered thread male fitting do not over tighten.
3. No warranty claims will be considered for damage due to incorrect installation.

Содержание aquashield centurion ASC50

Страница 1: ...ning will expose persons to the possibility of personal injury and may result in damage to the UV system or other property This unit is designed to treat water at ambient temperatures 5 C to 45 C Cont...

Страница 2: ...Power Surge Protection 4 Power Connection 4 Mounting Plumbing and Start Up 5 LED Indicators 6 Alarms 6 Maintenance 7 Cleaning the quartz sleeve 7 Changing the Filter Cartridge 8 Replacing the UV lamp...

Страница 3: ...alarm beeps on and off the lamp is due to be changed so that effective treatment is maintained Flashing of the red LED indicates that the lamp countdown timer is operating Recommendations for maintai...

Страница 4: ...from leaking pipe joints or seals Electrical Power Surge Protection An electrical power surge or spike can travel on the supply lines and cause serious damage to your electrical equipment The Steriflo...

Страница 5: ...lamp The lamp is shipped in a tube in the top of the box Carefully unwrap the lamp and slide it into the pre fitted quartz sleeve through the top of the endcap Connect the lamp connection plugs and p...

Страница 6: ...ashing of the red LED indicates normal operation and the lamp countdown timer is operating Should the unit alarm power to the pump will be interrupted ensuring safe water is always supplied Manual ove...

Страница 7: ...endcap from the sleeve Lift the quartz sleeve out of the chamber by pulling it straight up Try to handle the quartz sleeve by holding it by the top 2cm Try not to handle the quartz sleeve as fingerpr...

Страница 8: ...eaks 5 Screw the housing onto the lid and hand tighten Open the tap downstream of the filter and then open the inlet valve The cartridge spanner supplied with the unit may help if the housing is tight...

Страница 9: ...ld for approx 10 seconds The unit should beep to indicate the lamp life timer has been reset The timer will then count down for 12 months and beep alarm when the lamp needs to be replaced Securely wra...

Страница 10: ...xposure skin sloughing peeling weeping area sever sunburn symptoms FIRST AID EYES In mild cases if in doubt seek medical attention Severe cases cover eyes with gauze or clean cloth seek medical attent...

Страница 11: ...11...

Страница 12: ...ors loss or damage resulting from misuse or negligent handling improper use for which the product was not designed or advertised failure to properly follow the provided installation and operating inst...

Отзывы: