AXEL ULite Hardware Manual
v.1.0.2
6.1
Fixed HW peripherals
Fixed HW peripherals are the devices connected on dedicated pins and
are not to multiplexing and can not be multiplexed for other functionalities
In the sections below you can find the different standard devices within
their system configuration
6.1.1
Ethernet
On-board Ethernet PHY (Micrel KSZ8019RN) provides interface signals
required to implement the 10/100 Mbps Ethernet port. The transceiver is
connected to the triple speed Ethernet MAC (ENET module) through
RMII interface.
The following table describes the interface signals:
Pin Name
Pin
Internal Connections
Ball/pin #
ETH_LED1
J2.13
LAN.LED0/PME_N1
23
ETH_TX_P
J2.19
LAN.TXP
6
ETH_TX_M
J2.21
LAN.TXM
5
ETH_RX_P
J2.23
LAN.RXP
4
ETH_RX_M
J2.25
LAN.RXM
3
Tab. 15
: Ethernet interface signals