AXEL ULite Hardware Manual
v.1.0.2
7
Power, reset and control
AXEL ULite
system-on-module (SOM for short) is powered by carrier
board via
VIN_SOM
rail.
About voltage range, three supported configurations are available. These
configurations are indicated by the value of the
f
field of the ordering
code. The generic ordering code is in the form:
DA p l r n c f t s
The field
f
can assume the following values:
●
0,1: power supply voltage range 3.135 - 3.465V (that is
3V3±5%)
●
2: power supply voltage range is 3.3 - 4.5V
●
please note that this range can be widened by the use of an
external MOSFET; for more details please refer to
●
3: power supply voltage range is 3.25 - 3.465V (that us 3.3
+5%/-1.5%).
Voltage references for single-ended I/O signals the same for all
configurations. They are detailed in the following table.
Signal groups
Voltage
reference
SODIMM pin number
Nominal
voltage
UART1-UART5
CSI
LCD
NAND
SD1
JTAG
GPIO1
ENET1-ENET2
3V3_IO
155
3.3
SNVS_TAMPER[9:
0]
VDD_SNVS_
IN
143
3.0
What is interfaced to 3.3V signals at carrier board level may be
referenced to a different voltage than 3.3V_IO. However, the difference
August, 2019
53/65
Содержание Axel ULite
Страница 2: ...AXEL ULite Hardware Manual v 1 0 2 Page intentionally left blank August 2019 2 65...
Страница 6: ...AXEL ULite Hardware Manual v 1 0 2 August 2019 6 65...
Страница 13: ...Fig 2 AXEL ULite block diagram AXEL ULite Hardware Manual v 1 0 2 2 2 Block Diagram August 2019 13 65...
Страница 31: ...AXEL ULite Hardware Manual v 1 0 2 Tab 13 J2 odd pins 1 to 203 August 2019 31 65...
Страница 65: ...AXEL ULite Hardware Manual v 1 0 2 Fig 7 Accessing the RESERVED AREA August 2019 65 65...