Rev 0.11 

 

 

 

 

 

 

 

Page G.703-7 

Interface Parameter Detail (when G.703 is Active) 

Representation 

Type 

Entry 

Description 

G703P1 

InsMap 

TS08-On 

Selection 

TSxx 

– 0=Off, 1=On. 

xx = 01 to 31. 
Press Up/Down key to toggle 
between Off and On.  Press 
Left/Right keys to change 
Timeslot number.  Press 
enter to program all timeslots.  

Used for FractionalE1 mode to 
select which timeslots (1-31) 
that are to be inserted to the 
output E1 framed signal 
received over the satellite. 
Timeslot 16 not available in 
PCM30-CAS framing.  

Port 2 

 

 

 

G703P2 

TxMode 

E1 

Selection 

0=Disable 
1=E1 

Activate the G.703/E1 
interface Port 1 

G703P2 

TxCode 

HDB3 

Selection 

0=AMI 
1=HDB3 

Line Coding 

G703P2 

TxFrame 

PCM-31-CCS 

Selection 

0=Full E1  
1=PCM30-CAS 
2=PCM31-CCS 

Input Framing selection 

G703P2 

TxCRC4 

PCM-31 

Selection 

0=Disable 
1=Enable 

Cyclic Redundancy Check for 
error reporting 

G703P2 

TxNx64k 

512 kbps 

Read Only   

Display the Nx64kbps satellite 
rate 

G703P2 

DropMap 

TS08-On 

Selection 

TSxx 

– 0=Off, 1=On. 

xx = 01 to 31. 
Press Up/Down key to toggle 
between Off and On.  Press 
Left/Right keys to change 
Timeslot number.  Press 
enter to program all timeslots.  
 

Used for FractionalE1 mode to 
select which timeslots (1-31) 
that are to be dropped from 
the input E1 framed signal and 
transmitted over the satellite.  
Timeslot 16 not available in 
PCM30-CAS framing.  

Port 2 

 

 

 

G703P2 

RxMode 

E1 

Selection 

0=Disable 
1=E1 

Activate the G.703/E1 
interface Port 1 

G703P2 

RxCode 

HDB3 

Selection 

0=AMI 
1=HDB3 

Line Coding 

G703P2 

RxFrame 

PCM-31 

Selection 

0=Full E1  
1=PCM30-CAS 
2=PCM31-CCS 

Input Framing selection 

G703P2 

RxCRC4 

PCM-31-CCS 

Selection 

0=Disable 
1=Enable 

Cyclic Redundancy Check for 
error reporting 

G703P2 

RxNx64k 

512 kbps 

Read Only   

Display the Nx64kbps satellite 
rate 

G703P2 

InsMap 

TS08-On 

Selection 

TSxx 

– 0=Off, 1=On. 

xx = 01 to 31. 
Press Up/Down key to toggle 
between Off and On.  Press 
Left/Right keys to change 
Timeslot number.  Press 
enter to program all timeslots.  

Used for FractionalE1 mode to 
select which timeslots (1-31) 
that are to be inserted to the 
output E1 framed signal 
received over the satellite. 
Timeslot 16 not available in 
PCM30-CAS framing.  

 

 

 

 

Alarm 

TstActive 

to Alarm A 

Selection 

0=None, 1=A, 2=B, 3=A & B 

Selects destination of alarm 

Alarm 

BERLoss 

to Alarm B 

Selection 

0=None, 1=A, 2=B, 3=A & B 

Selects destination of alarm 

Содержание PSM-500

Страница 1: ...ard is not already installed in the modem refer to Section 4 for installation information Typical use of the G5 interface is in a duplex point to point link with a similarly configured PSM 500 series...

Страница 2: ...interface operates at a nominal rate of 2 048Mbps The data transferred over the E1 transport stream is organized in frames Each E1 frame contains 256 bits which are comprised of 32 timeslots each cont...

Страница 3: ...of voice and data channels share a separate channel that is used only for control signals This signaling protocol can be SS7 ISDN or PBX Switch Proprietary protocols The channel used for common channe...

Страница 4: ...G 703 E1 Interface from the front panel From the front panel you would select Intf I O Mode for the G 703 option This is accomplished by pressing the Int f button to the right of the LCD display then...

Страница 5: ...03 interface Other options may be added in the future I O RTS Ignore Selection 0 Normal 1 Control CXR 2 Ignore Interface RTS line control I O CTS Normal Selection 0 Normal 1 Force Active Interface CTS...

Страница 6: ...lection 0 Full E1 1 PCM30 CAS 2 PCM31 CCS Input Framing selection Full E1 Unframed Mode G703P1 TxCRC4 Enable Selection 0 Disable 1 Enable Cyclic Redundancy Check for error reporting G703P1 TxNx64k 512...

Страница 7: ...eys to change Timeslot number Press enter to program all timeslots Used for FractionalE1 mode to select which timeslots 1 31 that are to be dropped from the input E1 framed signal and transmitted over...

Страница 8: ...ion See Main User Manual for Description Test ModBER Disabled Selection 0 Disable 1 2047 2 2 23 1 3 Insert 1 Error if enabled BERT enable to modem transmit input Test DemodBER Disabled Selection 0 Dis...

Страница 9: ...t 1 Table 2 Port 1 Port 2 Connector 120 ohm Balanced Pinouts RJ48c Signal Name Description Direction Pins SD T Send Data Tip To Modem 1 SD R Send Data Ring To Modem 2 RD T Receive Data Tip From Modem...

Страница 10: ...ble for command line control and monitor of the Optional G5 processor card Table 4 Console Connector Pinouts 9 pin D female Signal Name Description Direction Pins Notes RXD Console RX From Modem 2 EIA...

Страница 11: ...voltages and result in harm to personnel and equipment 3 1 Installing the G5 Interface Position the rear option plate supplied into the chassis and align the mounting plate holes with the holes in the...

Страница 12: ...he receive data port by using the Local Loopback settings on the front panel Intf Test menu Refer to the front panel configuration menus in the PSM 500 I O Manual and Table 1 above for setup informati...

Страница 13: ...13 Verify that the BER tester is able to achieve data synchronization and there are no errors Once the test is finished remove the test mode by setting the IF Loopbck to Disable The unit is now ready...

Отзывы: