background image

for example, [ DATA ] in STAT mode and [ EXP ] key .

3)  Functions required inputing values before pressing the

function key, for example, cos, sin, tan, cos 

-1

, sin 

-1

, tan 

-1

,

log, ln, X 

2

, 1/x,

 √, π, 

3

√,

 X!, %, RND, ENG, 

→。

→。

→。

→。

→。,

,,

,, ,,

,,

,,

,,

,,,

,,

,,

。。

。。,

,,

,, ,,→

,,→

,,→

,,→

,,→,

 and 6 units conversion.

4)  Fractions
5)  +/–
6)  X 

y

y

7)  nPr, nCr
8)  x , ÷
9)  +, –

Correction

If you have made a mistake when entering a number (but you

have not yet pressed an arithmetic operator key), just press [ CE ] to
clear the last entry then input it again, or delete individual digits by
using the backspace key [ 00

0 ]

(Ex.) : Correct 12385 as 789

Step : press [ CE ] 789

DEG

789.

(Ex.) : Correct 12385 as 123

Step : press [ 00

0 ] twice

DEG

123.

In a series of calculations, you can correct errors in immediate

results by pressing [ ON/C ] to clear the calculation completely
(expect clearing memory, see page 9).

If you press the wrong arithmetic operation key,  just press [ CE ]

key before entering anything else.

Accuracy and Capacity

Accuracy :

   

±

1 in 10th digit.

Capacity :

In general, every reasonable calculation is displayed up to 10

digit mantissa, or 10-digit mantissa plus 2-digit exponent up to
10

±

99 

or integers between – 9999999999 and 9999999999.

Numbers used as input must be within the range of the given

function. The range for each of the calculator’s functions is given in
the following pages.

 

Functions

Input range

sin x, cos x, tan x

Deg

:│

X

│<

4.5 x 10

 

10 

deg

E - 5

X

Содержание DS-834

Страница 1: ... Root Power Root E 10 Logarithms and Antilogarithms E 10 Fraction calculation E 10 Angular units conversion E 11 Trigonometric Inverse trigonometric functions E 11 Hyperbolic Inverse hyperbolic functions E 12 Rectangular Polar coordinates E 12 Permutations Combinations E 12 Sexagesimal Decimal conversion E 13 Base n mode calculation E 13 Complex numbers calculation E 14 Random numbers and Exchange...

Страница 2: ...d as soon as possible To replace batteries 1 Remove the screws that hold the back cover 2 Remove the back cover 3 Replace the old batteries and install new ones with polarity in correct directions 4 Secure the screws in place then press ON C to turn the power on The keyboard Many of the calculator s keys are used to perform more than one function The functions marked on the keyboard are printed di...

Страница 3: ...imit HYP Hyperbolic mode Display format The calculator can display numbers in four formats floating point fixed point scientific and engineering Floating point display format The floating point format displays numbers in decimal form using up to 10 digits Any trailing zeros are truncated If the result of a calculation is too large to be represented in 10 digits the display automatically switches t...

Страница 4: ... floating point format Besides entry can be made in scientific notation by using the EXP key after entering the mantissa Ex Key the number 4 82296 x 10 5 Step key in 4 82296 EXP 5 DEG 4 82296 05 in floating point format Engineering display format The format is similar to the scientific format expect the mantissa can have up to three digits left of the decimal instead of only one and the exponent i...

Страница 5: ...5 as 123 Step press 00 0 twice DEG 123 In a series of calculations you can correct errors in immediate results by pressing ON C to clear the calculation completely expect clearing memory see page 9 If you press the wrong arithmetic operation key just press CE key before entering anything else Accuracy and Capacity Accuracy 1 in 10th digit Capacity In general every reasonable calculation is display...

Страница 6: ... x 10 99 X 1 x 10 100 10 x 1 x 10 100 X 100 e x 1 x 10 100 X 230 2585092 X 0 X 1 x 10 100 x 2 X 1 x 10 50 1 X X 1 x 10 100 X 0 3 X 1 x 10 100 X 0 X 69 X is an integer R P 1 x 10 100 P R 0 r 1 x 10 100 Deg θ 4 5 x 10 10 deg Rad θ 2 5 x 10 8 π rad Grad θ 5 x 10 10 grad however for tan x Deg θ 90 2n 1 Rad θ 2n 1 Grad θ 100 2n 1 n is an integer DD MM SS SS 1 x 10 100 0 MM SS SS x 1 x 10 100 X y X 0 1 ...

Страница 7: ...11111111 for negative OCT 0 X 3777777777 for zero or positive 4000000000 X 7777777777 for negative HEX 0 X 2540BE3FF for zero or positive FDABF41C01 X FFFFFFFFFF for negative Overflow Error conditions A symbol E are indicated on the display when any of the following conditions occur and further calculation becomes impossible Just press ON C to release those overflow or error indicator and the subs...

Страница 8: ... and remains in the display until the last parenthesis is closed 5 2 x 1 5 x 3 5 2 x 1 5 x DEG 2 8 0 8 x 4 3 0 8 x 4 2 x 7 6 x 5 4 2 x 7 6 x DEG 122 5 4 Note It is unnecessary to press the key before the key Constant calculation The calculator enables you to repeat the last number entered or the last operation executed by pressing key Repeating the last number 3 x 3 3 x DEG 9 3 x 3 x 3 DEG 27 3 x ...

Страница 9: ...nd when performing memory calculations 1 The M indicator appears when a number is stored in the memory 2 Recalling from a memory by pressing MR key does not affect its contents 3 All memories are unavailable under STAT mode 4 In order to exchange the content of the memory for the displayed number please press X M key 5 The contents of the memories can be cleared by pressing 0 X M or CE X M in sequ...

Страница 10: ...thms ln7 log100 7 ln 100 log DEG 3 95 10 2 2 2ndF 10 x DEG 100 00 e 5 e 2 5 2ndF e x DEG 148 28 2 2ndF e x Fractional calculation Fraction value display is as follow Note Total of integer numerator and denominator must be within 10 digits or the fractional value couldn t be shown completely By pressing 2ndF d e the displayed value will be converted to the improper fraction 7 2 a 3 DEG 8 4 15 8 7 a...

Страница 11: ...rees DEG radians RAD and grad GRAD The relation among the three angle units is 180 π rad 200 grad 1 To change the default setting to another setting press DRG key repeatedly until the angular unit you want is indicated in the display 2 After entering an angle press 2ndF DRG repeatedly until the converted value is displayed 90 deg 90 DEG 90 rad 2ndF DRG RAD 1 57 grad 2ndF DRG GRAD 100 00 Trigonomet...

Страница 12: ... θ i sin θ Note When using those key make sure the calculator is set for the angular unit you want Converting from Rectangular to Polar If a 5 and b 6 5 a 6 b DEG 7 81 what are r and θ 2ndF R P b DEG 50 19 Converting from Polar to Rectangular If r 25 and θ 56 25 a 56 b DEG 13 98 what are a and b 2ndF P R b DEG 20 73 Permutations Combinations nPr nCr How many 7 2ndF nPr 4 DEG 840 00 permutations of...

Страница 13: ...rting from Decimal to Sexagesimal 2 12345 2 12345 2ndF 2 7 24 42 Base n mode calculation Converting between bases The unit enables you to calculate in number base other than decimal The calculator can add subtract multiply and divide binary octal and hexadecimal numbers Select the number base you want by the BIN OCT HEX DEC keys The BIN OCT and HEX indicators show you which base you are using if n...

Страница 14: ...mplex numbers mode by pressing CPLX key and make sure CPLX indicator appears on the display The calculator enables you to add subtract multiply and divide complex numbers Complex numbers are generally represented as a b i where a is a real and b is imaginary 2ndF CPLX DEG CPLX 7 9 i 7 a 9 b 22 00 15 10 i 15 a 10 b b DEG CPLX 1 00 Note Memory calculation is available in complex number mode Random n...

Страница 15: ...lowing single variable statistics n number of all data Σ x sum of all data Σ x2 sum of the squares mean value s Sample Standard deviation σ Population standard deviation CP Precision capability CPK Process capability Min CPU CPL where CPU CPL Note In STAT mode all function key are available except base n calculation Ex 1 Enter the following data to calculate Σ x Σ x 2 n S CP and CPK where data 1 2...

Страница 16: ...are retained even if auto power off or turning off unless exiting STAT mode Viewing statistics data Pressing DATA or key under ED mode can view the statistics data you have entered The difference between DATA and is the item of the data entry appears 1 5 sec before the value by DATA the value appears immediately without the item by Ex 2 View the statistics data based on Ex 1 Step 0 Press 2ndF EDIT...

Страница 17: ...9 00 data 9 10 00 Editing statistics data Ex 4 Based on Ex 1 correct data 1 2 as data 1 3 Method 1 Press 2 2ndF DEL 3 to overwrite Method 2 Step 1 Press 2ndF EDIT DEG ED STAT 0 00 Step 2 Find out 2 by DATA or DEG ED STAT 2 00 Step 3 Enter 3 to overwrite 2 DEG ED STAT 3 Step 4 Press and 2ndF EDIT to exit ED mode where those data are changed as data 1 3 00 data 2 5 5 00 data 6 8 9 00 Ex 5 Based on E...

Страница 18: ...alue you can enter the value and the number of occurrences up to 255 The data based on Ex 1 can be rewritten and entered as follow Value Number of occurrences Alternative method 2 1 DATA 2 5 4 DATA 5 x 4 9 3 DATA 9 x 3 where data 1 2 data 2 5 5 data 6 8 9 Under ED mode when you continue choosing a value from data 2 5 and correcting it as 33 the permutation among those data will be changed as data ...

Отзывы: