Connections
7
Zone volume control
By means of this input the volume of an external zone can be adjusted. The volume control can be
connected in two different ways:
Supplying an external voltage
When a voltage is supplied between the tip and the shielding of one of the cinch-connectors the
volume will be attenuated (for both the left and the right channel). When a negative voltage is
supplied the signal will be amplified. The amplification ranges from +14...-80dB. The graph below
shows the amplification as function of the applied voltage:
Connecting a potentiometer
It is also possible to connect a potentiometer between the tip and the shielding to one of the cinch
connectors. The attenuation ranges from 0...-80dB. A 10kOhm logarithmically potentiometer gives
the best results. The next graph shows the attenuation as function of the angle of rotation:
As a maximum four
additional output zones can be connected.
When an adjustable attenuation is not necessary a cinch connector with a short-circuit between the
tip and shield must be connected. When the input is left open the volume will be fully attenuated.
-80
-70
-60
-50
-40
-30
-20
-10
0
10
20
-2
0
2
4
6
8
10
Voltage at 'volume control' (V)
0
10
20
30
40
50
60
70
80
90
0
10
20
30
40
50
60
70
80
90
100
Rotation angle potentiometer (%)