![Datcon DT4120 PS Series Скачать руководство пользователя страница 82](http://html1.mh-extra.com/html/datcon/dt4120-ps-series/dt4120-ps-series_operating-instructions-manual_513639082.webp)
DT4120 xx xx (PS)
82
20170324-V0
Communication interface (optional)
Type:
RS232 or RS485, (isolated)
Isolation voltage:
0.5 kV
RS485 termination resistance:
135 ohm, you can switch on by using a short
on the terminals
Baud rate:
300 / 600 / 1200 / 2400 / 4800 /
9600
Baud
Parity:
even
/ odd / none
Protocol:
MODBUS RTU slave
Address:
1-247 (factory setting:
0
)
Possible commands:
read of registers (3)
Ambient conditions
Operating temperature range
0-60 °C (-20 - +60 °C on request)
Storage temperature range
-25 - +70 °C
Climatic conditions:
EN 60654-1, class B2
Relative humidity:
90% (max., non-condensing)
Place of installation:
cabinet
Electromagnetic compatibility (EMC)
In accordance with the standard EN 61326-1:2006
Emission:
Conducted: EN
55011:1998
Limits for Class A equipments
Radiated: EN
55011:1998
Limits for Class A equipments
Immunity:
ESD:
4 kV/8 kV contact / air
-B- criteria
BURST:
2 kV/1 kV power / signal
-B- criteria
SURGE: 1
kV
-B-
criteria
Conducted RF:
3 Veff
-A- criteria
Содержание DT4120 PS Series
Страница 1: ...DT4120 xx xx PS Temperature Resistance Potentiometer Meter Transmitter Operating Instructions...
Страница 84: ...DT4120 xx xx PS 84 20170324 V0 10 2 Application example Analog output option...
Страница 85: ...DT4120 xx xx PS 20170324 V0 85 RS232 communication interface option...
Страница 86: ...DT4120 xx xx PS 86 20170324 V0 RS485 communication interface option...
Страница 87: ...DT4120 xx xx PS 20170324 V0 87 RS485 bus topology...
Страница 90: ...DT4120 xx xx PS 90 20170324 V0...
Страница 91: ...DT4120 xx xx PS 20170324 V0 91...
Страница 92: ......