DT1012 IP
20221107-V0
17
Connecting the instrument to 230 V AC/DC power supply
The following figure shows the wiring plan, connecting the instrument
to 230 V AC/DC power supply:
(note the information about the installation overcurrent protection
see chapter
10.1. Technical specification
)
Wiring plan connecting
to 230 V AC/DC power
supply
1. Loosen terminal screws.
2. Insert the wire ends into the open terminals according to the wiring
plan.
3. Screw the terminal in.
4. Check the hold of the wires in terminals by pulling on them firmly.
Checking the
connections
Check if the cables are connected properly (have you connected all
the cables, have you connected to the right place, do not the cable-
ends touch each other).
5.5. Switching on the power supply
Switching on the
power supply
Switch on the power supply.
If connected correctly, the green "on" indicator lights up and —
depending on the settings — an output signal proportional to the input
signal can be measured at the output.
Содержание DT1012 IP
Страница 1: ...DT1012 IP PS Temperature Resistance Potentiometer Transmitter Operating Instructions...
Страница 35: ...DT1012 IP 20221107 V0 35...
Страница 36: ......