port (LANC/BX-Lens) through a remote cable or via the RS-232/422 OUT port (RS-232/RS-422) through
an RJ-45 cable. For information about the remote cable, see the section on
See below for information about RJ-45 cabling (RS-422 wiring scheme between the camera
controller and PTR-10 MARK II) in the RS-422 setup.
Camera Controller (RJ-45 Port)
PTR-10 MARK II (RS-422 IN)
GND
1
White/Orange
White/Orange
1
GND
NC
2
Orange
Orange
2
NC
TX-
3
White/Green
White/Green
3
RX-
RX-
4
Blue
Blue
4
TX-
RX+
5
White/Blue
White/Blue
5
TX+
TX+
6
Green
Green
6
RX+
NC
7
White/Brown
White/Brown
7
NC
NC
8
Brown
Brown
8
NC
Please note that bit 4 of the DIP switch on PTR-10 MARK II devices must be set to OFF prior to
establishing physical connection. See the
section for detailed information.