Datavideo PTR-10 MARK II Скачать руководство пользователя страница 4

4

 

FCC Compliance Statement 

This  device  complies  with  part  15  of  the  FCC  rules.  Operation  is  subject  to  the  following  two 
conditions: 

(1)

 

This device may not cause harmful interference, and  

(2)

 

This device must accept any interference received, including interference that may cause 
undesired operation. 

Warnings and Precautions 

1.

 

Read all of these warnings and save them for later reference. 

2.

 

Follow all warnings and instructions marked on this unit. 

3.

 

Unplug this unit from the wall outlet before cleaning. Do not use liquid or aerosol cleaners. Use a 
damp cloth for cleaning. 

4.

 

Do not use this unit in or near water.  

5.

 

Do  not  place  this  unit  on  an  unstable  cart,  stand,  or  table.  The  unit  may  fall,  causing  serious 
damage. 

6.

 

Slots and openings on the cabinet top, back, and bottom are provided for ventilation. To ensure 
safe and reliable operation of this unit, and to protect it from overheating, do not block or cover 
these openings. Do not place this unit on a bed, sofa, rug, or similar surface, as the ventilation 
openings on the bottom of the cabinet will be blocked. This unit should never be placed near or 
over  a  heat  register  or  radiator.  This  unit  should  not  be  placed  in  a  built-in  installation  unless 
proper ventilation is provided. 

7.

 

This product should only be operated from the type of power source indicated on the marking 
label of the AC adapter. If you are not sure of the type of power available, consult your Datavideo 
dealer or your local power company. 

8.

 

Do not allow anything to rest on the power cord. Do not locate this unit where the power cord 
will be walked on, rolled over, or otherwise stressed. 

9.

 

If an extension cord must be used with this unit, make sure that the total of the ampere ratings 
on the products plugged into the extension cord do not exceed the extension cord rating. 

10.

 

Make sure that the total amperes of all the units that are plugged into a single wall outlet do not 
exceed 15 amperes. 

11.

 

Never push objects of any kind into this unit through the cabinet ventilation slots, as they may 
touch dangerous voltage points or short out parts that could result in risk of fire or electric shock. 
Never spill liquid of any kind onto or into this unit. 

12.

 

Except as specifically explained elsewhere in this manual, do not attempt to service this product 
yourself.  Opening  or  removing  covers  that  are  marked  “Do  Not  Remove”  may  expose  you  to 
dangerous  voltage  points  or other  risks,  and  will  void  your  warranty.  Refer  all  service issues to 
qualified service personnel. 

Содержание PTR-10 MARK II

Страница 1: ...ROBOTIC PTR 10 MARK II PAN TILT HEAD Instruction Manual...

Страница 2: ...3 2 VIDEO 13 4 CONTROL FUNCTIONS 14 4 1 RS 422 VISCA COMMUNICATION PROTOCOL 14 4 2 DVIP 16 4 3 REMOTE OUT 17 Remote Port 18 LANC 18 BX Lens 20 RS 232 422 OUT 20 RS 232 20 RS 422 20 4 4 TALLY 21 4 5 IR...

Страница 3: ...plete This manual may contain typing errors omissions or incorrect information Datavideo Technologies always recommend that you double check the information in this document for accuracy before making...

Страница 4: ...should not be placed in a built in installation unless proper ventilation is provided 7 This product should only be operated from the type of power source indicated on the marking label of the AC ada...

Страница 5: ...od begins on the thirtieth day after shipment from a Datavideo office All non Datavideo manufactured products product without Datavideo logo have only one year warranty from the date of purchase Damag...

Страница 6: ...collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environme...

Страница 7: ...Camera Controller RMC 300A Universal Remote Control Panel and is compatible with serial or Ethernet DVIP 1 1 Features Strong and sturdy aluminum frame Various interfaces SDI HDMI RS 232 RS 422 DVIP T...

Страница 8: ...8...

Страница 9: ...9 2 System Overview...

Страница 10: ...t output voltages that the DC OUT D tap connector is delivering See the section on DIP Switch for selection of output voltage Video 4 SDI IN Video IN from the mounted camera 5 SDI OUT Delivers camera...

Страница 11: ...uctions 12 REMOTE Connect through a remote cable to various camera brands in order to control camera s zoom and focus as well as other functions See the REMOTE section for cable pinout information con...

Страница 12: ...rate the PTR 10 MARK II by an IR remote control Firmware Upgrade Device Configuration 16 F W Upgrade For upgrading to the latest firmware See Firmware Update 17 DIP Switch For configuring the PTR 10 M...

Страница 13: ...upplied 12V 5A PSU The connection can be secured by screwing the outer fastening ring of the DC In plug to the socket D tap DC OUT 24W The D tap connector supplies DC power to the camera 3 2 Video SDI...

Страница 14: ...d 8 PTR 10 MARK II devices respectively See the diagrams below for example system setups RMC 180 Camera Controller RMC 300A Camera Controller To control the camera mounted on PTR 10 MARK II using the...

Страница 15: ...Controller RJ 45 Port PTR 10 MARK II RS 422 IN GND 1 White Orange White Orange 1 GND NC 2 Orange Orange 2 NC TX 3 White Green White Green 3 RX RX 4 Blue Blue 4 TX RX 5 White Blue White Blue 5 TX TX 6...

Страница 16: ...evices simultaneously For operation of the RMC 300A see the user manual for instructions In the second diagram the Showcast 100 4K ShowCast Streaming Studio communicates with the PTR 10 MARK II device...

Страница 17: ...and click the OK button 8 On the DVIP Device List you will then be able to see the Device Name MAC address and IP address of the connected device 9 Set the network to DHCP then click the Save button...

Страница 18: ...menu option Remote Out Mode on your PTR 10 MARK II device Follow the menu path below 4 Remote Control 6 Set Remote Out 1 Remote Out mode LanC or BX Lens LANC If the LANC mode is enabled connect the Re...

Страница 19: ...DC Input Accessible Functions PXW Z280V Sony 24 31 W 12V Zoom Focus Iris OSD Menu OSD Display Shutter White Balance Mode Gain and ND PXW Z190V Sony 22 29 W 12V PXW Z150 Sony 6 3 6 6 W 8 4V PXW X160 S...

Страница 20: ...Mode you may mount Datavideo s BC 80 or BC 200 on the PTR 10 MARK II and use a custom made RJ 45 cable to establish physical connection See below for pinout information RS 232 PTR 10 MARK II RS 232 4...

Страница 21: ...receives tally information from external devices such as a video switcher Tally OUT delivers tally information to the mounted camera Tally Light Definitions Message On Air Live Standby Cued Free Safe...

Страница 22: ...22 4 5 IR Remote Control Operates PTR 10 MARK II by an IR remote control...

Страница 23: ...sets allowing automatic movement of cameras to these positions in the order configured in the group Recalling Group The PTR 10 MARK II is equipped with 8 groups To recall a group first press the numbe...

Страница 24: ...SET button description Set up Group Scan mode Press any of the group numbers 1 8 and then press the GROUP button see the GROUP button description Return Camera Lens to the Front Press number 0 and the...

Страница 25: ...w less light to come in so that the subject appears less bright To cancel the function or return to default setup press the Auto button 11 ENTER ENTER Menu ENTER key 12 Direction Arrows Change camera...

Страница 26: ...n to wake the device from standby mode OSD Menu The OSD menu allows you to modify various device settings such as pan and tilt and control protocols Press the menu button on your remote control opens...

Страница 27: ...oup 7 8 Escape 9 Tilt Min Limit 9 Group 8 10 Tilt Max Limit 10 Escape 11 Escape Details of all options in the on screen menu are listed in the table below First Level Main Options Second Level Sub Opt...

Страница 28: ...T Max Limit 45 1 11 Escape 2 Memory 1 Preset Position 1 50 P T 1 P T Speed 1 18 2 Escape 51 ESCAPE 2 Group 1 1 16 PRESET NO 1 50 ITEM ON OFF ON OFF SPEED LIMIT 1 18 WAITING TIME 0 180 NEXT POSITION NE...

Страница 29: ...E 0 180 NEXT POSITION NEXT ITEM RETURN GROUP 1 GROUP 2 GROUP 3 GROUP 4 GROUP 5 GROUP 6 GROUP 7 GROUP 8 ESCAPE 17 ESCAPE 5 Group 4 1 16 PRESET NO 1 50 ITEM ON OFF ON OFF SPEED LIMIT 1 18 WAITING TIME 0...

Страница 30: ...1 18 WAITING TIME 0 180 NEXT POSITION NEXT ITEM RETURN GROUP 1 GROUP 2 GROUP 3 GROUP 4 GROUP 5 GROUP 6 GROUP 7 GROUP 8 ESCAPE 17 ESCAPE 8 Group 7 1 16 PRESET NO 1 50 ITEM ON OFF ON OFF SPEED LIMIT 1 1...

Страница 31: ...ize 1280 x 720 1920 x 1080 3840 x 2160 3 HDMI Mode RGB444 YUV422 4 Escape 4 Remote Control 1 PAN TILT Reverse OFF P T P T 2 Remote Source RS 422 SW Configurable using bottom DIP switch ONLY 3 Set RS 4...

Страница 32: ...Display P T OSD PAN OSD ON OFF TILT OSD ON OFF VZOOM OSD ON OFF ESCAPE DEBUG OSD DEBUG IR OSD ON OFF DEBUG RS 422 OSD ON OFF DEBUG DVIP OSD ON OFF DEBUG M_CTL OSD ON OFF DEBUG REG OSD ON OFF DEBUG FRA...

Страница 33: ...itch can be found on one of the system panels and allows the user to set the device s VISCA ID enable remote control DVIP or RS 422 configure the OSD menu size and select the DC output See the table b...

Страница 34: ...ocedure 1 Copy firmware image files MB and MCTL into the root directory of a USB hard drive 16 GB and insert it into the F W Upgrade USB port 2 Use the IR remote control to open the OSD menu Note If y...

Страница 35: ...overloaded the device power will be automatically disconnected To resume power first turn off the device unplug the power cable for more than 15 seconds then reconnect the power and turn on the device...

Страница 36: ...36 8 Dimensions PTR 10 MARK II All measurements in millimeters mm...

Страница 37: ...ontrol IR Remote Pan Tilt Range PAN 340 MAX TILT 45 to 45 MAX Pan Tilt Speed PAN 0 2 15 Sec TILT 0 1 10 Sec Presets 50 PAN TILT positions Control Distance RS 422 1200 m DVIP 100 m Control Protocol Son...

Страница 38: ...38 Storage Humidity 5 80 Weight 3 4 Kg Dimensions LxWxH 230 x 190 x 300 mm Optional Accessories ZEK 1 WM 10 WM 11 CM 10...

Страница 39: ...39 Notes...

Страница 40: ...Jan 10 2021 Version E1 Datavideo Technologies Co Ltd All rights reserved 2020 www datavideo com product PTR 10...

Отзывы: