Voice Commands for Rockwell Chip Set _____________________
The Voice Command
Command Function
A
Answering in Voice/Audio Mode
D
Dial command in Voice/Audio Mode
H
Hang up in Voice/Audio Mode
Z
Reset from Voice/Audio Mode
#BDR=n
Select baud rate (turn off autobaud) 0<n<48
#CID=n
Enable Caller ID detection and select reporting format n=0~2
#CLS=n
Select data, fax, or Voice/Audio n=0,1,2,8
#MDL? Identify
model
#MFR? Identify
manufacturer
#REV?
Identify revision level
#TL
Audio output transmit level
#VBQ?
Query buffer size
#VBS=n
Bits per sample (ADPCM or PCM) n=2,4,8
#VBT=n
Beep tone timer n =0~40 (0-4 seconds)
#VCI?
Identify compression method (ADPCM)
#VLS=n
Voice line select (ADPCM or PCM) n=@~9
#VRA
Ringback goes away timer (originate)
#VRN
Ringback never came timer (originate)
#VRX
Voice Receive Mode (ADPCM or PCM)
#VSD
Enable silence deletion (voice receive, ADPCM)
#VSK=n
Buffer skid setting n=255
#VSP
Silence detection period (voice receive, ADPCM)
#VSR
Sampling rate selection (ADPCM or PCM)
#VSS
Silence detection tuner (voice receive, ADPCM)
#VTD
DTMF tone reporting capability
#VTM
Enable timing mark placement
#VTS
Generate tone signals
#VTX
Voice transmit mode (ADPCM or PCM)
Page: 10