120 20170-204a
Paragon
PD
Technical Manual
27
Table 9 - Checklist A (after installation)
CHECKLIST A
(Paragon
PD
)
Recommended Check out after Installation
Step
ACTION
EXPECTED RESULTS at
25
°°°°
C
MEASURE WITH
IF NOT?
1
Normal Power-up
Sequence
BDLC
PD
beeps once, all LEDs come ON for about four seconds, the green LEDs
then flash in a “ripple” pattern for close to two seconds. All LEDs go OFF except the
CK that should flash 6 to 8 times per second. For functions, see section 3.2.1.2
2
Connect and save
unit config
Press WinRIS
Get
button
3
Transmitter Output
Power
Press
TX (Unmod)
VHF/UHF
: 100 watts
800
: 70 watts
+10%, -10%
Factory-settable down to
10 watts as per customer
request.
Service monitor set to
read power
or
150W in-line watt-
meter installed as
close as possible to
the unit antenna con-
nector.
Refer to Checklist
B
4
Transmitter
Reflected Power
Press
TXON (Un-
mod)
<5% of forward power or as
specified by Syst. Eng.
10W in-line wattmeter
Check for bad connections,
damaged coax cable, etc.
5
RF Link test
Use the addressing
function’s “Send”
button to dynami-
cally test transmis-
sions
Look for
“Delivery confirmed” on the
Status bar
as per sections
Mobile is out of range
Refer to factory technical
support.
1
(unless unit has been set a lower value). Note that readings less than 100 watts for VHF/UHF or 70 watts for 800 MHz models,
may be due to losses in cables used for testing. Check also your wattmeter frequency calibration curve. Do not be too ready to
condemn the transmitter or the RF feedline & antenna installation.
Содержание Paragon
Страница 34: ......
Страница 64: ...120 20170 204a ParagonPD Technical Manual 56 Figure 31 T885 Receiver Tuning Controls Location...
Страница 65: ...120 20170 204a ParagonPD Technical Manual 57 Figure 32 T881 Exciter Tuning Controls Locations...
Страница 67: ...120 20170 204a ParagonPD Technical Manual 59 Figure 34 T857 Exciter Tuning Controls Locations TCXO...