120 20170-204a
Paragon
PD
Technical Manual
20
•
An
RSSI Bar Graph
on the right side of the
window is exclusive to Gemini
PD
and is dis-
abled for Paragon
PD
.
4.4 Port
Configuration
Window
At program’s launch, WinRIS opens the “Port
Configuration window”.
Enter the COM port and speed that should be
used. The program defaults to 8 bits, no parity
and one stop bit. Make necessary modifica-
tion(s) to entries if needed and click on Save to
go to main screen (a delay of several seconds
may occur). If COM port and speed are already
saved, the program automatically goes to the
main screen.
1.
In the COM Port list box, select the COM
port (1,2,3 or 4) to use for connection.
Note: the COM Ports selections numbered 5
to 32 are used (at factory) to upgrade sev-
eral units from the same computer USB
port.
2.
In the Baud rate list box, select the baud rate
to use that matches your unit. The available
choices are 4800, 9600, 14400, 19200 or
38400.
3.
Bits options are 7 or 8 (default)
4.
Parity options are N (default), odd or even
5.
Stop bits options are 0, 1 (default) or 2
Make the relevant entry in the “Connection
Type --- Base Only” box as follows:
1.
In the first drop-down list-box, select either
“Direct connected” or “Connected via an
MSC”.
•
If the selection was
Direct connected,
The second drop-down list box is avail-
able, select either “Using DMP” or
“Using MSCP”.
The Logical Tower ID single-line entry
box is not available.
•
If the selection was
Connected via a
MSC,
The second drop-down list box is not
available.
The Logical Tower ID single-line entry
box is available. Enter the relevant
Logical ID.
The Logical ID is a unique number as-
signed to the MSC-tower-base link when
the MSC is configured. Logical ID
numbers for MSC-tower-base links are
usually assigned numbers 1 to 100,
leaving numbers 101-126 for use with
Hosts.
2.
Click the Save button to validate your
choice(s) and start the connecting process.
To exit the window without making any change,
click on Cancel.
Notes:
Enable the “Always ask port configuration
when WinRIS start” box to have the Port Con-
figuration window always opening at start up.
Two instances of WinRIS may be run. One ap-
plication runs on one COM port and the second
on another port. This feature allows testing a
mobile and a base station on one computer that
has two COM ports.
Ensure that mobile unit is in DMP mode.
4.5 Functions
The WinRIS program is used to:
•
Save an existing configuration from a unit to
a file.
•
Take a configuration from a file and upload
it to a unit
•
Check Paragon
PD
’s transmit functions
•
Test and/or trouble-shoot installations
4.5.1 “Station Reset” button
On the menu bar, select “Test”, then the “Sta-
tionreset” command or press the “Stationreset”
button on the Toolbar to issue a stationreset
command to the modem.
The Stationreset button is pressed as a last step
after doing a “Put From”. It causes downloaded
parameters from a file or diskette to take effect
in the connected unit.
Pressing Stationreset is not required after doing
any Comments or Password configuration
Содержание Paragon
Страница 34: ......
Страница 64: ...120 20170 204a ParagonPD Technical Manual 56 Figure 31 T885 Receiver Tuning Controls Location...
Страница 65: ...120 20170 204a ParagonPD Technical Manual 57 Figure 32 T881 Exciter Tuning Controls Locations...
Страница 67: ...120 20170 204a ParagonPD Technical Manual 59 Figure 34 T857 Exciter Tuning Controls Locations TCXO...