120 20170-204a
Paragon
PD
Technical Manual
24
Table 8 - Carrier deviations for Tone or Data Modulation
Carrier Modulation
Tone
Data
Network Speed
(b/s)
Typical deviation in
kHz
TX test tone in ( )
Absolute
Maximum
deviation
in kHz
Full Channel (800MHz) U.S. & Canada
32000
± 3.5
(1000 Hz)
± 5.3 *
25600
± 3.7
(1000 Hz)
± 5.7 *
x
RC4F
S
K
19200
± 4.3
(1000 Hz)
± 6.2 *
Full Channel (UHF) U.S. & Canada
32000
±4.3
(1000 Hz)
±6.3*
25600
±4.0
(1000 Hz)
±6.0*
x
RC4F
S
K
19200
±4.5
(1000 Hz)
±6.5*
Full Channel (UHF & 800MHz) U.S. & Canada
19200
± 4.0
(1000 Hz)
± 4.7
16000
± 4.0
(1000 Hz)
± 4.7
DGF
S
K
9600
± 3.0
(1000 Hz)
± 3.6
NPSPAC 800 MHz - 12.5 kHz channel spacing U.S.
DGF
SK
9600
± 2.5
(1000 Hz)
± 2.9
14400
± 2.7
(1000 Hz)
± 3.6
16000
± 2.4
(1000 Hz)
± 3.2
19200
± 2.1
(1000 Hz)
± 2.8
x
RC4F
S
K
25600
± 2.0
(1000 Hz)
± 2.7
Half-Channel UHF - U.S. & UHF + 800MHz - Canada
DG
FSK
9600
± 2.5
(1000 Hz)
± 2.9
14400
± 2.0
(1000 Hz)
± 2.9
16000
± 1.6
(1000 Hz)
± 2.3
x
RC4F
S
K
19200
1.5
± 2.0
* Deviation shown may seem higher than normal, however
they fall within the following appropriate FCC’s masks lim-
its.
1-
Specify the address:
Addresses may be entered by typing directly
in the “Address” field in two ways:
-
Numerically, the valid address range is
1-126.
-
As an “Alpha-Mapped-Nibble” (AMN)
address, consisting of upper case letters
in the range A-P. The valid address
range is A to GN.
-
The base address is usually: 1.
-
The program may display one of the
following messages on the status bar:
-
For Paragon products:
“Address is not in AMN or number
format”
-
For mobile products:
“Address is not in the range A – GN”
In either case, check that the address entered is
within the acceptable range, is of a valid format
and correctly typed.
2-
Enter the Device number for mobile (or base
station).
3-
Press the Send button.
The Chat window reports “Sent to xx mobile”
(where xx is mobile name)
.
If test is successful:
Status line reports “Delivery confirmed.
If test unsuccessful:
Chat window reports “Waiting”,
Then the Status line reports “Delivery Failed”.
4.5.6 Status
Bar
The Status Bar is located along the bottom edge
of the WinRIS window. To display or hide the
bar, check or uncheck the command in the
“View” menu.
The left area of the status bar describes actions
of menu items as you navigate using the direc-
tional arrows. This area also shows messages
describing actions of toolbar buttons as you de-
press them, before releasing them. If after
viewing the description of the toolbar button
command you wish not to execute the command,
then release the mouse button while the pointer
is off the toolbar button.
Содержание Paragon
Страница 34: ......
Страница 64: ...120 20170 204a ParagonPD Technical Manual 56 Figure 31 T885 Receiver Tuning Controls Location...
Страница 65: ...120 20170 204a ParagonPD Technical Manual 57 Figure 32 T881 Exciter Tuning Controls Locations...
Страница 67: ...120 20170 204a ParagonPD Technical Manual 59 Figure 34 T857 Exciter Tuning Controls Locations TCXO...