9. MIB Definitions
rss16RackName 1.3.6.1.4.1.1418.1.1.1
This read/write variable is the name of the rss16 chassis. This variable can be programmed either via SNMP,
Telnet or via serial port. It can contain printable characters and MUST not exceed 20 characters in length.
rss16CardTable 1.3.6.1.4.1.1418.1.1.2
This variable is not directly accessible.
rss16CardEntry 1.3.6.1.4.1.1418.1.1.2.1
This variable is not directly accessible.
rss16CardIndex 1.3.6.1.4.1.1418.1.1.2.1.1.rss16CardIndex
The card index. This is a 0 based index so 0 is card 1 and 15 is card 16.
rss16CardName 1.3.6.1.4.1.1418.1.1.2.1.2.rss16CardIndex
This read/write variable is used to set or get the name of an individual A/B card. The card name can only
contain printable ASCII characters and MUST not exceed 20 characters in length.
rss16CardPosition 1.3.6.1.4.1.1418.1.1.2.1.3.rss16CardIndex
This read/write variable can be used to set or get the position of any of the 16 A/B cards individually. This
variable uses an enumerated integer where:
1 = a
2 = b
3 = disabled
4 = invalidCardIndex
The values 3 and 4 cannot be used in the set command. These are returned by the get and set commands
when appropriate.
rss16CardEnable 1.3.6.1.4.1.1418.1.1.2.1.4.rss16CardIndex
This read/write variable is used to set or get the enabled/disabled status of an A/B card. It uses an
enumerated integer where:
1 = enabled
2 = disabled
3 = invalid index
The value 3 cannot be used in the set command. It is returned by both the set and get commands when the
card index is invalid.
rss16GangControl 1.3.6.1.4.1.1418.1.1.3
This read/write variable is used to set the position of all cards in the chassiss. It uses an enumerated integer
where:
1 = a
2 = b
3 = writeOnly