10baseT Connector  

The 10baseT connector is located on the rear panel of the IPAL.  It provides connection to the Ethernet.   

  
Note: Connection to an Ethernet hub is made using the cable provided. To directly connect to a PC, a crossover 
cable is required. This cable is available at any computer store. 

 

An LED on the jack indicates when the connection to the network is properly established 
 

Serial Connection   * for models without internal modem * 

This connection provides for RS-232 connection for out-of-band connection to the iPAL.  A terminal or modem can be 
attached directly to this 9 pin connector.  With a modem attached, connection is made using PPP (Dial-up-Networking) and 
Telnet.   
 
 
Connection directly to a laptop or terminal requires a null modem (crossover) cable.   
 
With a terminal directly installed, a simple menu interface is used. These menus are identical to the telnet setup and control 
screens. Use any terminal emulation software to connect to the iPAL.  
 

Connection parameters are: 19200bps, 8 data bits, 1 stop bit, no parity (19200,8,n,1).  Set flow control to OFF

Serial Port pinout: 

 

Pin No 

Description 

Data Carrier Detect 

Receive Data 

Transmit Data 

Data Terminal Ready 

Signal Ground 

Data Set Ready 

Request to Send 

Clear to Send 

Ring Indicator 

 

Modem Connection  * for models with internal modem * 

The RJ11 jack marked LINE if for direct connection to a telephone line.

iP-815

iP-815-M

Crossover
Cable

Dial-up

Dial-up to 
computers running 
Dial-up Networking
Telnet and/or Web 

Direct Connect
to Terminal
Emulation

Dial-up

OR

External
Modem

Straight
Cable

D9-RJ Adpater
# 1940149

Содержание IP-410 -

Страница 1: ...ed outlets for use on 115 VAC 15 Amp Service NEMA N5 15 iP 810 8 switched outlets for use on 115 230 VAC 12 10 Amp International IEC 320 iP 410 4 switched outlets for use on 115 230 VAC 12 10 Amp Inte...

Страница 2: ...se a 3 to 2 prong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to rest on the power cord Do not locat...

Страница 3: ...115VAC 10base T J2 Serial J1 Expansion J3 Model iP 420 M iP 415 M 8 NEMA 5 15 Outlets 115VAC 10base T J2 Internal Modem J1 Expansion J3 Model iP 810 8 IEC320 Outlets 115 230VAC 10base T J2 Serial J1...

Страница 4: ...directly to a laptop or terminal requires a null modem crossover cable With a terminal directly installed a simple menu interface is used These menus are identical to the telnet setup and control scr...

Страница 5: ...upport tech dataprobe com or 201 967 8788 A C Power Connections The iP 820 iP 420 provide a linecord for connection to a 20 Amp 115VAC service The total maximum current load for all outlets on the iP...

Страница 6: ...the following command arp s IP Address MAC Address Where IP Address is the desired IP address for the iPAL and the MAC address is the MAC Address of the iPAL The MAC Address of the iPAL is located on...

Страница 7: ...A Using Make a New Connection in Dial up Networking setup a Dial Up Networking connection Set the desired modem and telephone number you wish to use Now right click and choose properties of the Dial u...

Страница 8: ...ing icon you have just created No user name or password is required Click on Connect B Once a Dial Up Networking connection has been established you can access the iPAL using any telnet A web browser...

Страница 9: ...r re set to factory defaults should they become inadvertently changed The iPAL system is capable of controlling up to eight outlets Model s iP 410 and iP 415 provide only four outlets with room for ex...

Страница 10: ...me 10 X Return to the Main Menu Enter Circuit Names For All Models Each circuit outlet can be identified with a 20 character name for easy identification Select 1 from the Setup menu A list of all eig...

Страница 11: ...password required for Telnet and Web Browser Access To change the password Select 4 from the Setup Menu The password can be up to 8 characters and is case sensitive Please remember your password If yo...

Страница 12: ...and Enter at the prompt You can change all circuits simultaneously by selecting A and Enter for All The feedback column confirms that the switch command you selected has been carried out If this colu...

Страница 13: ...onfiguration Remember the password is case sensitive When the password is properly entered click OK This brings up the Control and Status screen This screen provides all the control and status informa...

Страница 14: ...iPAL Page 14 Upon completion of your control session click on logout This will terminate the session and release iPAL to the next user The Goodbye page will be displayed...

Страница 15: ...le 16 Amps combined total of all receptacles iP 815 iP 415 Main Power Input Standard NEMA 5 15 Plug on 6 foot 14 3 line cord 120VAC Output Circuits Standard NEMA 5 15 Receptacle Current Maximums 12 Am...

Страница 16: ...01 967 8788 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shipment THIS WARRANTY DO...

Отзывы: