Important Safety Instructions    

 
When using this product, basic safety precautions should always be followed to reduce the risk of fire, electric 
shock, and injury to persons, including the following: 
 

1.  Read and understand all instructions. 

2.  Follow all warnings in the manual and marked on the product.  

3.  Unplug this product from the wall outlet before cleaning.  Do not use liquid cleaners or aerosol cleaners.  Use a damp cloth 
for cleaning. 

4.  Do not use this product in an outdoor environment or near water, for example, near a bath tub, wash bowl, kitchen sink, or 
laundry tub, in a wet basement, or near a swimming pool. 

5.  Do not place this product on an unstable cart, stand, or table.  The product may fall, causing serious damage to the 
product. 

6.  Slots and openings in this product  and the back or bottom are provided for ventilation to protect it from overheating, these 
openings must not be blocked or covered.  The openings should never be blocked by placing the product on the bed, sofa, 
rug, or other similar surface.  This product should never be placed near or over a radiator or heat register.  This product 
should not be placed in a built-in installation unless proper ventilation is provided. 

7.  This product should be operated only from the type of power source indicated on the marking label.  If you are not sure of 
the type of power supply to your home, consult your dealer or local power company. 

8.  This product is equipped with a three wire grounding type plug, a plug having a third (grounding) pin.  This plug will only fit 
into a grounding type power outlet.  This is a safety feature.  If you are unable to insert the plug into the outlet, contact your 
electrician to replace your obsolete outlet.  Do not defeat the safety purpose of the grounding type plug.  Do not use a 3-to-2 
prong adapter at the receptacle; use of this type adapter may result in risk of electrical shock and/or damage to this product. 

9.   Do not allow anything to rest on the power cord.  Do not locate this product where the cord will be abused by persons 
walking on it. 

10.  Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock.  

11.  Never push objects of any kind into this product through slots as they may touch dangerous voltage points or short out 
parts that could result in a risk of fire or electrical shock.  Never spill liquid of any kind on the product. 

12.  To reduce the risk of electrical shock, do not disassemble this product, but take it to a qualified serviceman when some 
service or repair work is required.  Opening or removing covers may expose you to dangerous voltages or other risks.  
Incorrect re-assembly can cause electric shock when the appliance is subsequently used.  

13.  Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions: 

a)  When the power supply cord or plug is damaged or frayed. 

b)  If liquid has been spilled into the product. 

c)  If the product has been exposed to rain or water. 

d)  If the product does not operate normally by following the operating instructions.  Adjust only those controls, that are 
covered by the operating instructions because improper adjustment of other controls may result in damage and will often 
require extensive work by a qualified technician to restore the product to normal operation. 

e)  If the product has been dropped or has been damaged. 

f)  If the product exhibits a distinct change in performance. 

14.  Avoid using a telephone (other than a cordless type) during an electrical storm.  There may be a remote risk of electric 
shock from lightning. 

15. Do not use the telephone to report a gas leak in the vicinity of the leak. 

16. Do not exceed the maximum output rating of the auxiliary power receptacle. 

Содержание IP-410 -

Страница 1: ...ed outlets for use on 115 VAC 15 Amp Service NEMA N5 15 iP 810 8 switched outlets for use on 115 230 VAC 12 10 Amp International IEC 320 iP 410 4 switched outlets for use on 115 230 VAC 12 10 Amp Inte...

Страница 2: ...se a 3 to 2 prong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to rest on the power cord Do not locat...

Страница 3: ...115VAC 10base T J2 Serial J1 Expansion J3 Model iP 420 M iP 415 M 8 NEMA 5 15 Outlets 115VAC 10base T J2 Internal Modem J1 Expansion J3 Model iP 810 8 IEC320 Outlets 115 230VAC 10base T J2 Serial J1...

Страница 4: ...directly to a laptop or terminal requires a null modem crossover cable With a terminal directly installed a simple menu interface is used These menus are identical to the telnet setup and control scr...

Страница 5: ...upport tech dataprobe com or 201 967 8788 A C Power Connections The iP 820 iP 420 provide a linecord for connection to a 20 Amp 115VAC service The total maximum current load for all outlets on the iP...

Страница 6: ...the following command arp s IP Address MAC Address Where IP Address is the desired IP address for the iPAL and the MAC address is the MAC Address of the iPAL The MAC Address of the iPAL is located on...

Страница 7: ...A Using Make a New Connection in Dial up Networking setup a Dial Up Networking connection Set the desired modem and telephone number you wish to use Now right click and choose properties of the Dial u...

Страница 8: ...ing icon you have just created No user name or password is required Click on Connect B Once a Dial Up Networking connection has been established you can access the iPAL using any telnet A web browser...

Страница 9: ...r re set to factory defaults should they become inadvertently changed The iPAL system is capable of controlling up to eight outlets Model s iP 410 and iP 415 provide only four outlets with room for ex...

Страница 10: ...me 10 X Return to the Main Menu Enter Circuit Names For All Models Each circuit outlet can be identified with a 20 character name for easy identification Select 1 from the Setup menu A list of all eig...

Страница 11: ...password required for Telnet and Web Browser Access To change the password Select 4 from the Setup Menu The password can be up to 8 characters and is case sensitive Please remember your password If yo...

Страница 12: ...and Enter at the prompt You can change all circuits simultaneously by selecting A and Enter for All The feedback column confirms that the switch command you selected has been carried out If this colu...

Страница 13: ...onfiguration Remember the password is case sensitive When the password is properly entered click OK This brings up the Control and Status screen This screen provides all the control and status informa...

Страница 14: ...iPAL Page 14 Upon completion of your control session click on logout This will terminate the session and release iPAL to the next user The Goodbye page will be displayed...

Страница 15: ...le 16 Amps combined total of all receptacles iP 815 iP 415 Main Power Input Standard NEMA 5 15 Plug on 6 foot 14 3 line cord 120VAC Output Circuits Standard NEMA 5 15 Receptacle Current Maximums 12 Am...

Страница 16: ...01 967 8788 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shipment THIS WARRANTY DO...

Отзывы: