Important Safety Information 

 
When using this product, basic safety precautions should always be followed to reduce the risk of fire, electric 
shock, and injury to persons, including the following: 
 

Disconnect all power cords before servicing! 

 

1.  Read and understand all instructions. 

2.  Follow all warnings in the manual and marked on the product.  

3.  Unplug this product from the wall outlet before cleaning.  Do not use liquid cleaners or aerosol cleaners.  Use a damp cloth for cleaning. 

4.  Do not use this product in an outdoor environment or near water, for example, near a bath tub, wash bowl, kitchen sink, or laundry tub, in a 
wet basement, or near a swimming pool. 

5.  Do not place this product on an unstable cart, stand, or table.  The product may fall, causing serious damage to the product. 

6.  Slots and openings in this product and the back or bottom are provided for ventilation to protect it from overheating, these openings must not 
be blocked or covered.  The openings should never be blocked by placing the product on the bed, sofa, rug, or other similar surface.  This 
product should never be placed near or over a radiator or heat register.  This product should not be placed in a built-in installation unless proper 
ventilation is provided. 

7.  This product should be operated only from the type of power source indicated on the marking label.  If you are not sure of the type of power 
supply to your home, consult your dealer or local power company. 

8.  This product is equipped with a three wire grounding type plug, a plug having a third (grounding) pin.  This plug will only fit into a grounding 
type power outlet.  This is a safety feature.  If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete 
outlet.  Do not defeat the safety purpose of the grounding type plug.  Do not use a 3-to-2 prong adapter at the receptacle; use of this type adapter 
may result in risk of electrical shock and/or damage to this product. 

9.   Do not allow anything to rest on the power cord.  Do not locate this product where the cord will be abused by persons walking on it. 

10.  Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock.  

11.  Never push objects of any kind into this product through slots as they may touch dangerous voltage points or short out parts that could result 
in a risk of fire or electrical shock.  Never spill liquid of any kind on the product. 

12.  To reduce the risk of electrical shock, do not disassemble this product, but take it to a qualified serviceman when some service or repair 
work is required.  Opening or removing covers may expose you to dangerous voltages or other risks.  Incorrect re-assembly can cause electric 
shock when the appliance is subsequently used.  

13.  Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions: 

a)  When the power supply cord or plug is damaged or frayed. 

b)  If liquid has been spilled into the product. 

c)  If the product has been exposed to rain or water. 

d)  If the product does not operate normally by following the operating instructions.  Adjust only those controls, that are covered by the operating 
instructions because improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician 
to restore the product to normal operation. 

e)  If the product has been dropped or has been damaged. 

f)  If the product exhibits a distinct change in performance. 

14.  Avoid using a telephone (other than a cordless type) during an electrical storm.  There may be a remote risk of electric shock from lightning. 

15.  Do not use the telephone to report a gas leak in the vicinity of the leak. 

16.  Do not exceed the maximum output rating of the auxiliary power receptacle. 

 

Содержание iBootBar iBB-2C10

Страница 1: ...ial Control iBB N20 M NEMA 20 Amp 8 x NEMA 5 15 IP Control Serial Control Internal Modem iBB 2N20 2 x NEMA 40 Amp 8 x NEMA 5 15 IP Control Serial Control iBB 2N20 M 2 x NEMA 40 Amp 8 x NEMA 5 15 IP Co...

Страница 2: ......

Страница 3: ...eration 13 Web Interface Command Line Interface Outlet Commands User Commands Device Commands Group Commands Web Server Commands Telnet Commands AutoPing Commands Event Commands Firmware Upload Comman...

Страница 4: ...rounding type plug Do not use a 3 to 2 prong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to rest on...

Страница 5: ...off outlet 1 iBootBar set outlet 1 off To reboot outlet 2 iBootBar set outlet 2 cycle Outlet Status Indicators Reset Pushbutton Recessed Mains Inlet Power Indicators Linecord for NEMA Models Circuit B...

Страница 6: ...uration Multiple users with assigned rights and simultaneous control Up to 16 users can be assigned administrator or user only rights plus access to specific outlets and groups Users only see the outl...

Страница 7: ...d Control functions can be linked to any SNMP v1 compatible manager The iBootBar MIB is downloadable from the website Syslog reporting All activity can be reported to a syslog compatible server iBootB...

Страница 8: ...inout Dial Line Models with suffix M have an internal modem This modem supports both data and DTMF control The modem is approved for use in 36 countries See Appendix for complete modem certifications...

Страница 9: ...national applications and can be used on 100V to 240VAC The iBB 2C10 provides two IEC 320 style universal inlets for connecting a detachable power cord Two standard IEC to CEE7 European cord sets are...

Страница 10: ...en saved configurations for change management 6 Clone saved configurations for replication of similar configurations in multiple iBootBars 7 Upload modified configurations to iBootBars 8 Control Power...

Страница 11: ...fault IP address 192 168 0 254 There are three techniques to setting the IP address of the iBootBar 1 Terminal Client software via Telnet Serial Modem 2 Automatically from a DHCP Server 3 ARP Ping fac...

Страница 12: ...ess is nn nn nn nn nn nn Windows 98 and Later 1 Access the iBootBar CLI and enter the set ipmode arp ping command 2 On a PC open a DOS window Run Command 3 Type the following command arp s IP Address...

Страница 13: ...on Global To see the status of the AutoPing feature click on AutoPing Control The Control panel provides the clickable buttons to change status of one or more outlets Once one or more outlets have bee...

Страница 14: ...ent alarms are highlighted in yellow Group View The Group Veiw displays the status of a single group Groups are two or more outlets linked together for simultaneous control In the group view each devi...

Страница 15: ...us of the AutoPing The numeric column will display the number of times the AutoPing has been triggered A numeric counter other than 0 with the status reporting OK indicates that there have been previo...

Страница 16: ...d state The user must have rights to the selected outlet This command is for iBootBars not used in a cluster configuration If used in a cluster it is the same as device 1 No get device 1 16 devname ou...

Страница 17: ...the root iBootBar s user table 20 character max Yes set user username device 1 16 devname all outlet 1 8 all yes no Sets the users right to the selected outlet on a specific device Yes No Rights set u...

Страница 18: ...the cycle time in seconds No 10 set cycle 1 99 get delay Get or set the delay time in seconds No 1 set delay 1 99 get current alarm High and Low alarms are used to monitor current conditions and send...

Страница 19: ...ns A device ID of 1 makes the unit a master and a device ID of 2 16 make the iBB a remote in cluster configurations These commands are only valid when directly connected to the iBootBar rather than as...

Страница 20: ...ic outlet on a specific device from the selected group Yes ren group groupname newname Renames the selected group 20 characters max Yes del group groupname Deletes the selected group Yes Network Comma...

Страница 21: ...web ssl yes no Enable or disable the root iBootBars web server s SSL capabilities Yes No Telnet Commands Command Description Admin Fact Def get telnet Returns the current settings of the root iBootBa...

Страница 22: ...set autoping 1 16 frequency 1 999 Set the frequency of the selected autoping in seconds Yes 10 set autoping 1 16 count 1 99 Set the number of failures the select autoping requires before it triggers i...

Страница 23: ...on off cycle Set the event action Yes set event eventname repeat never daily weekly monthly annually Set the event repeat Yes set event eventname control outlet 1 8 Sets the outlet that will be contro...

Страница 24: ...set time server ip address Sets the address of a NTS server for the root iBootBar to query Yes 129 6 15 29 set time usents yes no Enables or disables the root iBootBar s ability to connect to an NTS Y...

Страница 25: ...BootBar V1 5x Page 25 Firmware Upload Commands Command Description Admin Fact Def get upload enable Get or set the ability for the root iBootBar to accept a firmware upload Yes set upload enable Yes N...

Страница 26: ...or power cycle the outlet for the time configured with the CLI command cycle time The new status of the outlet is stated If the key is used the iBootBar will also state begin to indicate the reboot o...

Страница 27: ...ssign the event to a specific outlet or group and then configure the initial occurrence of the event the action to be performed and the repeat frequency if desired To configure the timed events use th...

Страница 28: ...ssigned outlet When the ping response returns iBootBar will power the off the outlet Off Latch Upon triggering iBootBar will power off the assigned outlet and remain so until changed via the web or te...

Страница 29: ...ress 192 168 1 7 Action Cycle Frequency 30 Count 3 Outlet Cabinet_1 Firewall Status OK OK iBootBar To configure the AutoPing use the following commands set autoping 1 16 ipaddress dotted decimal set a...

Страница 30: ...rned on or off for that user set user name email email address 64 char max set user name sendmail yes no Emails generated by iBootBar will display the device outlet s command along with the user and m...

Страница 31: ...sContact Truncated to 128 Char 5 RW DisplayString sysName Truncated to 128 Char 6 RW DisplayString sysLocation Truncated to 128 Char 7 RO INTEGER sysServices Firmware Upgrades The iBootBar can be upgr...

Страница 32: ...ement 6 Clone saved configurations for replication of similar configurations in multiple iBootBars 7 Upload modified configurations to iBootBars 8 Control Power Outlets on one or more iBootBars throug...

Страница 33: ...14 8 x C13 I S iBB 2C10 M 2 x C14 8 x C13 I S M iBB C20 C20 8 x C13 I S iBB C20 M C20 8 x C13 I S M iBB 2C20 2 x C20 8 x C13 I S iBB 2C20 M 2 x C20 8 x C13 I S M Key Input N15 NEMA 5 15 Linecord 115VA...

Страница 34: ...ith Part 15 of the FCC rules Operation of this device is subject to the following conditions 1 This device may not cause harmful interference and 2 this device must accept any interference that may ca...

Страница 35: ...rycode Argentina 07 Latvia 253 Australia 09 Liechtenstein 253 Austria 253 Lithuania 253 Belgium 253 Luxembourg 253 Brazil 22 Malaysia 108 Bulgaria 253 Malta 253 Canada 181 Mexico 181 Chile 153 Netherl...

Страница 36: ...RO Integer32 snmpManagerIndex 2 RW DisplayString snmpManagerIPAddress 3 RW INTEGER Enum snmpManagerEnable 3 TB outletTable 1 TE outletEntry 1 RO Integer32 outletIndex 2 RW OCTET STRING outletName 3 RO...

Страница 37: ...tained by contacting your Authorized Dataprobe Reseller THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT MISUSE ABUSE OR NEGLECT SELLER MAKES NO EXPRESS WARRANTIES OTHE...

Отзывы: