IMPORTANT SAFETY INSTRUCTIONS

 

 
When using this product, basic safety precautions should always 
be followed to reduce the risk of fire, electric shock, and injury to 
persons, including the following: 

 

1. Read and understand all instructions. 
2. Follow all warnings and marked on the product.  
3. Unplug this product from the wall outlet before cleaning.  Do not use liquid cleaners 

or aerosol cleaners.  Use a damp cloth for cleaning. 

4. Do not use this product in an outdoor environment or near water, for example, near 

a bath tub, wash bowl, kitchen sink, or laundry tub, in a wet basement, or near a 
swimming pool. 

5. Do not place this product on an unstable cart, stand, or table.  The product may fall, 

causing serious damage to the product. 

6. Slots and openings in this product  and the back or bottom are provided for 

ventilation to protect it from overheating, these openings must not be blocked or 
covered.  The openings should never be blocked by placing the product on the bed, 
sofa, rug, or other similar surface.  This product should never be placed near or over 
a radiator or heat register.  This product should not be placed in a built-in installation 
unless proper ventilation is provided. 

7. This product should be operated only from the type of power source indicated on 

the marking label.  If you are not sure of the type of power supply to your home, 
consult your dealer or local power company. 

8. This product is equipped with a three wire grounding type plug, a plug having a third 

(grounding) pin.  This plug will only fit into a grounding type power outlet.  This is a 
safety feature.  If you are unable to insert the plug into the outlet, contact your 
electrician to replace your obsolete outlet.  Do not defeat the safety purpose of the 
grounding type plug.  Do not use a 3-to-2 prong adapter at the receptacle; use of 
this type adapter may result in risk of electrical shock and/or damage to this product. 

9. Do not allow anything to rest on the power cord.  Do not locate this product where 

the cord will be abused by persons walking on it. 

10. Do not overload wall outlets and extension cords as this can result in the risk of fire 

or electric shock.  

11. Never push objects of any kind into this product through slots as they may touch 

dangerous voltage points or short out parts that could result in a risk of fire or 
electrical shock.  Never spill liquid of any kind on the product. 

12. To reduce the risk of electrical shock, do not disassemble this product, but take it to 

a qualified  serviceman when some service or repair work is required.  Opening or 
removing covers may expose you to dangerous voltages or other risks.  Incorrect 
re-assembly can cause electric shock when the appliance is subsequently used.  

13. Unplug this product from the wall outlet and refer servicing to qualified service 

personnel under the following conditions: 

a)   When the power supply cord or plug is damaged or frayed. 
b)   If liquid has been spilled into the product. 
c)  If the product has been exposed to rain or water. 
d)  If the product does not operate normally by following the operating 

instructions.  Adjust only those controls, that are covered by the operating 
instructions because improper adjustment of other controls may result in 
damage and will often require extensive work by a qualified technician to 
restore the product to normal operation. 

e)  If the product has been dropped or has been damaged. 
f)  If the product exhibits a distinct change in performance. 

14.  Avoid using a telephone (other than a cordless type) during an electrical storm.  

There may be a remote risk of electric shock from lightning. 

15.  Do not use the telephone to report a gas leak in the vicinity of the leak. 
16.  Do not exceed the maximum output rating of the auxiliary power receptacle. 
 

SAVE  THESE  INSTRUCTIONS 

Содержание iBoot

Страница 1: ...n 9 Setting IP Address Using DHCP Using Web Browser Access Using ibootrst exe Using ARP Ping Web Browser Operation 12 Password Protection Control Status Page Setup Page Passwords Page Forgotten Passwo...

Страница 2: ...ong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to rest on the power cord Do not locate this product...

Страница 3: ...ps 10 Amps at 230VAC Uses for iBoot Remote reboot of any device routers servers kiosks etc The device to be rebooted need not be network attached Secure sensitive devices by keeping them powered off w...

Страница 4: ...reboot it automatically when it no longer responds Use Auto Ping Remotely Put iBoot at a central facility to monitor a remote system and power up an alert when the remote device no longer responds Up...

Страница 5: ...disconnect the iBoot from the AC power source before making any control connections 10 100 Ethernet Power Input IEC 320 Male Line Cord Incuded for North America Power Input Selector 115 230 VAC Power...

Страница 6: ...ovided Use the Uplink jack to connect to an Ethernet hub and the Downlink jack to connect to an additional piece of networking equipment An LED next to each indicates when the connection to the networ...

Страница 7: ...Connect to Power Source Use Included Cord for North America For other locations use locally approved power cord 1 2 3 Connect Powered Device Use either IEC to NEMA Extension Cord supplied OR IEC to IE...

Страница 8: ...device to be power controlled The iBoot can be connected to a power strip to allow simultaneous control of multiple devices Make sure that the combined load of all controlled devices does not exceed 1...

Страница 9: ...et Mask and Gateway to the iBoot If you power up iBoot without a fixed static IP address the DHCP server will be able to assign an IP address This is the factory default setting for iBoot Once an IP a...

Страница 10: ...r ibootrst exe For iboot exe http www dataprobe com files power iboot exe To use ibootrst exe the computer running the program must be on the same subnet and network segment as the iBoot is to be prog...

Страница 11: ...d the MAC address is the MAC Address of the iBoot The MAC Address of the iBoot is located on bottom of the unit Example arp s 63 211 86 165 00 50 c2 05 01 c1 enter new IP addr MAC addr 3 Ping the iBoo...

Страница 12: ...rd if it has been changed A Username is not required When the proper password is received the Control and Status Page is displayed Control and Status Page Once the password is entered the following pa...

Страница 13: ...dow without first clicking Logout there will be a two minute delay before you can re access iBoot iBoot uses an inactivity timer for security When there is no activity for 2 minutes the user is logged...

Страница 14: ...he top of the page The new IP address will not take effect until the unit is rebooted Subnet Mask Change if required Consult your network manager for more details This will be automatically set if usi...

Страница 15: ...on When the ping response returns iBoot will power off Power Off Latch Upon loss of ping response iBoot will power off and remain so until changed via the web ibootctl exe or direct messaging Power Of...

Страница 16: ...for each password being changed OOPS I forgot my Password Well we told you to remember it but we understand You can reset iBoot to its factory default conditions Dataprobe provides a iBoot Reset Progr...

Страница 17: ...r ibootctl exe or http www dataprobe com files power iboot exe for ibootctl exe and ibootrst exe the reset program Direct TCP Telnet Control For application developers iBoot also supports control via...

Страница 18: ...Input 3 Prong Male IEC 320 input connector Input Cord Spec 16AWGX3C 10A 250 UL CSA VDE Rated 1 25mm 2 X3C Voltage Range Selectable 115 or 230 VAC Switched Receptacle 3 Prong Female IEC Capacity 12 Amp...

Страница 19: ...al Service at 201 967 8788 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shipment T...

Страница 20: ...functions be enabled User selectable security call processing and power control features are examples of such capabilities Visit www dataprobe com power ppal html Remote Power Control Console Port Ac...

Отзывы: