Web Browser Operation 

Password Protection 

iBoot uses two passwords, one for normal use and one that also 
provides access to the setup functions.  From the factory, both 
passwords are the same.  (PASS) 
 
Open your browser and enter the IP address of iBoot into the 
address bar.  If your have changed the IP address by any of the 
methods listed above, enter that address, otherwise, use the 
default IP address 

192.168.1.254 

 

Enter the default password 

PASS

, or your password if it has 

been changed.  A Username is not required.  When the proper 
password is received the Control and Status Page is displayed. 

Control and Status Page 

 
Once the password is entered, the following page is displayed.  
 (Only one person can be connected to the iBoot at a time.) 
 
 
 

Device Name 
 
 
Power Status 
 
 
Action Buttons 
 
Power Cycle Time 
 
Click  to  
Refresh Status 
 
Click for Logout 
 
Click for Setup 

(only seen if the Setup  
Password is used) 

 
To control the power, click on the appropriate button.  During 
power cycling, the Power Status bar will indicate the temporary 
status, with a blue background.  Once the cycle is complete, the 
status bar will revert to its original condition.  To abort a power 

Содержание iBoot

Страница 1: ...n 9 Setting IP Address Using DHCP Using Web Browser Access Using ibootrst exe Using ARP Ping Web Browser Operation 12 Password Protection Control Status Page Setup Page Passwords Page Forgotten Passwo...

Страница 2: ...ong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to rest on the power cord Do not locate this product...

Страница 3: ...ps 10 Amps at 230VAC Uses for iBoot Remote reboot of any device routers servers kiosks etc The device to be rebooted need not be network attached Secure sensitive devices by keeping them powered off w...

Страница 4: ...reboot it automatically when it no longer responds Use Auto Ping Remotely Put iBoot at a central facility to monitor a remote system and power up an alert when the remote device no longer responds Up...

Страница 5: ...disconnect the iBoot from the AC power source before making any control connections 10 100 Ethernet Power Input IEC 320 Male Line Cord Incuded for North America Power Input Selector 115 230 VAC Power...

Страница 6: ...ovided Use the Uplink jack to connect to an Ethernet hub and the Downlink jack to connect to an additional piece of networking equipment An LED next to each indicates when the connection to the networ...

Страница 7: ...Connect to Power Source Use Included Cord for North America For other locations use locally approved power cord 1 2 3 Connect Powered Device Use either IEC to NEMA Extension Cord supplied OR IEC to IE...

Страница 8: ...device to be power controlled The iBoot can be connected to a power strip to allow simultaneous control of multiple devices Make sure that the combined load of all controlled devices does not exceed 1...

Страница 9: ...et Mask and Gateway to the iBoot If you power up iBoot without a fixed static IP address the DHCP server will be able to assign an IP address This is the factory default setting for iBoot Once an IP a...

Страница 10: ...r ibootrst exe For iboot exe http www dataprobe com files power iboot exe To use ibootrst exe the computer running the program must be on the same subnet and network segment as the iBoot is to be prog...

Страница 11: ...d the MAC address is the MAC Address of the iBoot The MAC Address of the iBoot is located on bottom of the unit Example arp s 63 211 86 165 00 50 c2 05 01 c1 enter new IP addr MAC addr 3 Ping the iBoo...

Страница 12: ...rd if it has been changed A Username is not required When the proper password is received the Control and Status Page is displayed Control and Status Page Once the password is entered the following pa...

Страница 13: ...dow without first clicking Logout there will be a two minute delay before you can re access iBoot iBoot uses an inactivity timer for security When there is no activity for 2 minutes the user is logged...

Страница 14: ...he top of the page The new IP address will not take effect until the unit is rebooted Subnet Mask Change if required Consult your network manager for more details This will be automatically set if usi...

Страница 15: ...on When the ping response returns iBoot will power off Power Off Latch Upon loss of ping response iBoot will power off and remain so until changed via the web ibootctl exe or direct messaging Power Of...

Страница 16: ...for each password being changed OOPS I forgot my Password Well we told you to remember it but we understand You can reset iBoot to its factory default conditions Dataprobe provides a iBoot Reset Progr...

Страница 17: ...r ibootctl exe or http www dataprobe com files power iboot exe for ibootctl exe and ibootrst exe the reset program Direct TCP Telnet Control For application developers iBoot also supports control via...

Страница 18: ...Input 3 Prong Male IEC 320 input connector Input Cord Spec 16AWGX3C 10A 250 UL CSA VDE Rated 1 25mm 2 X3C Voltage Range Selectable 115 or 230 VAC Switched Receptacle 3 Prong Female IEC Capacity 12 Amp...

Страница 19: ...al Service at 201 967 8788 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shipment T...

Страница 20: ...functions be enabled User selectable security call processing and power control features are examples of such capabilities Visit www dataprobe com power ppal html Remote Power Control Console Port Ac...