4.3. 

Control and Status Page 

Once the user is validated, the Control and Status  page is 
displayed.  (Only  one  person  can  be  connected  to  the 
iBoot-PoE-P at a time.). 
 
This page provides automatic updates every 5 seconds.   
 
To  control  the  power,  click  on  the  appropriate  button.  
During power cycling, the Power Status bar will indicate the 
temporary status, with a blue background.  Once the cycle 
is  complete,  the  status  bar  will  revert  to  its  original 
condition.    To  abort  a  power  cycle,  click  on  either  Power 
On or Power Off buttons.   
 
If  the  AutoPing  and/or  Traffic  Monitor  features  are  in  use, 
the page  will also display  the current status, OK or Failed, 
for each, with a counter of how many times action was triggered.  If connecting with the Admin credentials, 
reset buttons for the Trigger counter is provided.   
 
If the iBoot-PoE-P is connected to a time server (see Section 5.4), The Home page will also show the five 
most  recent  history  events,  including  the  Outlet,  Action,  User  and  Time/Date  of  each  event.    The  iBoot-
PoE-P holds the last 32 events in memory.  The user can access a complete history webpage, download 
the history in a .csv file, or clear the history.   
 

Navigation Links 

Refresh 
  Use the Refresh link to obtain the latest status of iBoot-PoE-P.  Using your browser's refresh button can 
lead  to  inadvertent  power  switching.    If  an  NTP  server  is  being  used,  the  time  of  the  last  refresh  will  be 
shown in the upper right corner. 
 

Setup 
  To  access  the  Setup  page,  the  administrator  credentials  are  required.    When  logged  in  as  User,  the 
challenge for Administrator credentials will be displayed. 
 

Logout 
  When  you  are  finished  with  iBoot-PoE-P,  click  on 
Logout.  A Goodbye page will be displayed.  This page 
has  a  URL  link  to  re-connect  with  the  iBoot.    The 
linkback URL is user settable.  If no linkback is set, the 
hyperlink will be the unit’s IP Address. 

 

 

 

 

Содержание iBoot PoE-P

Страница 1: ...ty 31 Congratulations on purchasing the best network controlled power switch available The iBoot PoE P provides you the ability to reboot crashed devices automatically or with the click of a mouse Be...

Страница 2: ...Reboot iBoot PoE P has a web server built in as well as the ability to be managed through the iBoot Cloud Service A simple Web browser interface makes it easy to control power from anywhere in the wo...

Страница 3: ...it is also possible to turn ON or OFF the PD when the trigger conditions are met See Section 5 5 On AutoPing Setup Traffic Monitor Traffic Monitor measures the bandwidth utilization and reboots the PD...

Страница 4: ...mputer control URL Control You can send a single URL to the iBoot PoE P containing all the information necessary to query or change the power status This makes it easy to create a single button on you...

Страница 5: ...ctor Auto Configuration can also be initiated via the web page setup See Section 5 5 2 2 Hardware Connections iBoot PoE P supports 10 100 1000 Ethernet using the cable supplied or other suitable unshi...

Страница 6: ...Voltage on all pins 1 DC DC 2 DC DC 3 DC DC 4 DC DC 5 DC DC 6 DC DC 7 DC DC 8 DC DC Power Output on the PoE OUT connector will be identical to whatever mode is used on the NET IN connector 2 4 Mountin...

Страница 7: ...he iBoot PoE P Obtain and use the DMU 1 Download the latest version of the DMU at dataprobe com support iboot poe Run DMUSetup exe 2 Run the DMU Note The IP address can only be set within the first tw...

Страница 8: ...utton Get all the details on the DMU at http dataprobe com support dmu 3 3 Other ways to set the IP Address 1 Web Browser via the Set up Page See Section 5 2 Command Line Interface See Section 9 3 4 A...

Страница 9: ...setup or Command Line Interface See Section 5 5 for an explanation of these settings AutoPing Setting Address IP Address of Powered Device Frequency 10 Seconds Fail Count 3 Mode Single Action Cycle Re...

Страница 10: ...tes Setting to zero disables the timeout feature When there is no activity for the set time in minutes the user is automatically logged out and the username and password will need to be entered again...

Страница 11: ...ded If the iBoot PoE P is connected to a time server see Section 5 4 The Home page will also show the five most recent history events including the Outlet Action User and Time Date of each event The i...

Страница 12: ...not significant The user and password are not required when Auto Login feature is enabled see Section 5 7 for security options Examples http 192 168 1 254 s 1 u user p user Turn the outlet on for the...

Страница 13: ...emote firmware upgrades of the iBoot PoE P When this box is unchecked firmware upgrades will not be allowed Auto Logout This setting sets the automatic logout for inactivity on both the web and telnet...

Страница 14: ...able Cloud Services This setting enables the iBoot PoE P for iBoot Cloud Services iBCS iBCS allows the iBoot PoE P to be monitored and controlled from a web portal from any browser It allows multiple...

Страница 15: ...oth AutoPings need to exceed their fail count to trigger the Action With OR the Action will be triggered if either AutoPing fails Action Select from None AutoPing is paused No Ping tests will be perfo...

Страница 16: ...fic Subsequent reboots will occur when the time equals the Restart Time plus the Fail Time Number of Cycles Set the number of reboots to attempt for a single failure event Minimum Traffic Sets the min...

Страница 17: ...de supports both User and Admin users Each user has a settable password Auto Login This mode does not require a username of password for the User level operation No login challenge will be required fo...

Страница 18: ...will not allow programming for On Follow Off Latch or Off Follow If a Schedule Settings event has action for Off it will be reprogrammed for On Schedule Settings will not allow programming for action...

Страница 19: ...ice name when on the local network By default the name is iBoot PoE P xxxx where the xxxx is the last 4 segments of the MAC address for your iBoot PoE P When you reprogram the name of the device a reb...

Страница 20: ...Boot firmware may be made available and necessary to keep current with the cloud development The full Terms of Service of the iBoot Cloud Service is available here While the Cloud Service is in Beta s...

Страница 21: ...click on Add Device and enter the activation code in the field provided Congratulations You are now on the cloud d iBCS Main Page The iBCS main web page provides the ability to control your iBoot PoE...

Страница 22: ...to Password Enter the admin or user password and press Enter The prompt will change to iBoot This indicates successful login Enter commands as needed When done enter the logout command Note The telnet...

Страница 23: ...etwork This command will return all the network settings as shown below Mode DHCP IP Address 192 168 1 254 Subnet 255 255 255 0 Gateway 192 168 1 1 DNS 8 8 8 8 HTTP Port 80 Linkback URL Telnet Port 23...

Страница 24: ...decimal or name This command is used to set the address of AutoPing 1 or AutoPing 2 Use IP Address or domain name set autoping 1 2 frequency 1 999 This command is used to set the frequency how often t...

Страница 25: ...the stop disable time 00 00 get traffic monitor Traffic Monitor Enabled or Disabled Fail Time in seconds Restar Time in seconds Number of Cycles Minimum Bandwidth as programmed Maximum Test enabled d...

Страница 26: ...d to set the Address of a network time server ip or FQDN time nist gov get time Displays the current time and time server settings Current Time 07 30 2015 10 41 05 Timezone 5 DST Enabled Starts the 2n...

Страница 27: ...at the user is presented with Password This prompts the user to enter his password iBoot This is the prompt that will be displayed after the user has successfully logged in iBoot Reboot Required This...

Страница 28: ...es for the upgrade before making changes to you iBoot PoE P 1 Insure that the Upgrade Enable checkbox is checked in the Network Setup web page of the iBoot PoE P 2 Run the Device Management Utility av...

Страница 29: ...e output status 5 Seconds push Reset to Factory Defaults Hold the button in until the Outlet LED is blinking then release Hold in while and Power up the iBoot Recovery Mode Allows upload of new firmwa...

Страница 30: ...ce FCC Part 15 Class B CE Emission EN 55032 2012 AC 2013 CISPR 32 2012 Class B AS NZS CISPR 32 2013 EN 61000 3 2 2014 and EN 61000 3 3 2013 Immunity EN 55024 2010 A1 2015 IEC 61000 4 2 2008 IEC 61000...

Страница 31: ...r this Warranty is obtained by contacting your Authorized Dataprobe Reseller THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT MISUSE ABUSE OR NEGLECT SELLER MAKES NO EX...

Отзывы: