Replacing the SFP Module
The Arqa RX1/F and TX1/F are supplied with 2 SFP modules. One is installed and one is provided for the
endpoint module:
To replace the SFP:
1. Remove the black dust protector from the SFP module.
2. Pull the metal lever down until it reaches an angle of 45 degrees and gently slide out the module.
3. Insert the required module and lock into place by pushing the locking lever up into the locked position.
Note:
We recommend the use of SFP modules supplied by Datapath Ltd.
Mounting Options
Mounting Pads and Feet
The mounting pads and rubber feet can be used to hold the units in place and prevent them from
sliding on most surfaces.
To attach the mounting pads or rubber feet:
Remove the protection layer from the mounting pads or rubber feet.
Attach the mounting pads or rubber feet to the base of the unit.
14
Arqa User Guide