background image

Introduction

 

 

 

1

 
 
 
 
 
 
 

DNS-2670 Overview 

 
 

Form Factor 

4U 70-bay 3.5" 

Drive Support 

12Gb/s & 6Gb/s SAS 3.0 HDD and SSD 

Drive Form Factor 

3.5" Disk Device (2.5” Optional) 

I/O Controller 

Dual Redundant 12Gb/s SAS 3.0 Controller Module 

Host Interface 

Eight 12Gb/s SAS 3.0 SFF-8644 connections per I/O 

SAS Expander 

Avago|LSI 12Gb/s SASx48 48-port expander 

Controller Support 

12Gb/s SAS HBA 

Server Host Support 

Supports up to Eight Server/Host with eight host interface 

Disk Drive 

70 x 12Gb/s or 6Gb/s dual-ported SAS SSD & HDD 

Enclosure Cooling 

Twelve Cooling Fan Module built-in Power Module 

Power Supply 

1023W Lite-On

®

 2+2 Redundant Power Supply 

LED Indicators 

*Identify Enclosure               *Power On & Activity              *Drive Fault         
*Identify Drive                         *Drive Rebuild 

Enclosure Dimensions 

7” H x 19” W x 37.5” D 

Weight 

Enclosure only: 110lbs               with 70 drives: 275lbs 

Failure Notification 

SCSI Enclosure Services (SES-3) over in-band & LEDs 

 
 
 

1

 

Содержание DNS-2670

Страница 1: ...DNS 2670 User Manual DataON Storage storage division of Area Data Systems Version Dec 2015 ...

Страница 2: ......

Страница 3: ...stall the power supply 14 2 4 3 5 SATA SAS HDDs 15 2 4 1 To remove a HDD 15 2 4 2 To install a HDD 16 2 5 3 5 SATA SAS HDD Backplanes 18 2 5 1 To remove the backplane 18 2 5 2 To install the backplane 19 2 6 SAS IO Module 20 2 6 1 To remove the SAS I O Module 20 2 6 2 To install the SAS I O Module 20 2 7 Power Supplies 21 2 7 1 To remove the System Fans 21 2 7 2 To install the System Fans 22 Appen...

Страница 4: ...Chapter 1 Introduction ...

Страница 5: ...roller Support 12Gb s SAS HBA Server Host Support Supports up to Eight Server Host with eight host interface Disk Drive 70 x 12Gb s or 6Gb s dual ported SAS SSD HDD Enclosure Cooling Twelve Cooling Fan Module built in Power Module Power Supply 1023W Lite On 2 2 Redundant Power Supply LED Indicators Identify Enclosure Power On Activity Drive Fault Identify Drive Drive Rebuild Enclosure Dimensions 7...

Страница 6: ...DNS 2670 configuration server system can support two SIM SAS IO Module nodes 1 1 System Overview 1 1 1 System Top View Figure 1 1 System Top View 1 SIM Nodes 1 2 Upper Lower 2 System Fan Module 3 HDDs for SIM Nodes 1 2 2 ...

Страница 7: ...ont view of this DNS 2670 allows easy access to seven HDD backplanes In addition seven backplanes with HDD LEDs are located on the front Figure 1 2 System Front View 1 7 HDD Backplane 8 HDD Activity LED 9 HDD Fail LED 10 HDD Online LED 3 ...

Страница 8: ...buttons and LEDs and four power supplies Figure 1 3 System Back View 1 Power Button SW 2 4 6 8 10 12 14 16 Mini SAS HDD Connector 3 5 7 9 11 13 15 17 SAS Port Link Status LED 18 Expander RJ45 Network Connector 19 Expander RJ45 UART Debug Connector 20 System Power LED 21 System Fail LED 22 System UID LED 4 ...

Страница 9: ...Ds are failed or HDD backplane power fails Blinking HDD is locating or RAID is rebuilding HDD Online Green On HDD is installed Off No HDD 1 2 2 Back View LEDs The detailed LED information on the back is shown below Table 1 2 LED Information Type of LED Color Status Function Mini SAS HDD Link Status LEDs Green Red Green on Red off Mini SAS HDD s link successful Green off Red off Mini SAS HDD s link...

Страница 10: ...off or disable by other SIM System UID LED Blue Blinking SIM is identifying Off SIM is normal 1 3 Key Parts for Replacement SAS I O Module Part DNS 2670 IOM Fan Module Part DNS 2670 CFK Drive Blade Part DNS 2670 DB10 7 ...

Страница 11: ...Hardware 2 5 Drive Tray Part DNS 2670 DB2 3 5 Drive Tray Part DNS 2670 DB3 Power Supply Part DNS 2670 PSM 8 ...

Страница 12: ...1 4 DNS 2670 Block Diagram 9 ...

Страница 13: ...Hardware ...

Страница 14: ...Chapter 2 Removing and Installing Hardware 11 ...

Страница 15: ...e HDDs installed is over 100kg it requires two more persons to lift with suitable tools 2 1 Before You Start Take note of the following operations before you start to remove or install internal components To reduce the risk of injury from electric shock remove the power cord to completely disconnect power from the system Moving the Power On Off switch to the Off position does not completely remove...

Страница 16: ... install the top front cover chassis cover please follow the step below Step 1 Make sure all of the SIM nodes are not turned on and the server is not connected to AC power 2 2 1 To remove the chassis cover Release the screw on the top front chassis cover Slide the front cover horizontally to the front and remove it along the direction of thearrow Figure 2 2 Removing the Top Front Chassis Cover 13 ...

Страница 17: ...y Pull down the handle Press the retaining clip to the right side along the direction of the arrow At the same time pull out the power supply The power supply takes considerable force to remove Figure 2 8 Removing the Power Supply 2 3 2 To install the power supply Insert the replacement power supply firmly into the bay The retaining clip should snap Connect the AC power cord to the replacement pow...

Страница 18: ... Step 2 Remove the chassis cover To remove the chassis cover see 0 To remove the chassis cover Step3 Disconnect all necessary cables Take note of the drive tray orientation before sliding it out The tray will not fit back into the bay if inserted incorrectly 2 4 1 To remove a Disk Push the release button Pull the lever open Slide the Disk assembly out of the Disk bay Figure 2 10 Removing the Disk ...

Страница 19: ...o the Disk tray Figure 2 12 Placing the Disk to the Disk Tray Secure the Disk to the Disk tray with four screws Figure 2 13 Fastening the Screws Carefully insert the Disk assembly into the Disk bay with the lever lifted until it completely enters the Disk bay Push the lever back in place 16 ...

Страница 20: ...Hardware Operations Figure 2 14 Installing the Disk Assembly Make sure that the Disk is connected to the Disk connector on the backplane 17 ...

Страница 21: ... Make sure all of the SIM nodes are not turned on and the server is not connected to AC power Step 2 Remove the chassis cover To remove the chassis cover see 0 To remove the chassis cover Step 3 Remove the HDDs To remove the HDDs see 2 5 1 To remove a HDD Step 4 Disconnect all necessary cables 2 5 1 To remove the backplane Remove the screw that secures the backplane assembly Figure 2 15 Loosening ...

Страница 22: ...Hardware Operations Figure 2 16 Removing the Backplane Assembly Loosen the screws that secure the backplane 2 5 2 To install the backplane Reverse the steps above to install the backplane 19 ...

Страница 23: ...ear chassis cover is installed when removing or installing any SIM nodes to prevent the docking board connectors on theinterposer board from damage 2 6 1 To remove the SIM node Press the retaining latch Slide the SIM node out of the chassis by using the handle Figure 2 18 Removing the Node 2 6 2 To install the SIM node Push the SIM node into the chassis until it s completely seated in place Figure...

Страница 24: ...install the system fans please follow the steps below Step 1 Make sure all of the SIM nodes are not turned on and the server is notconnected to AC power Step 2 Remove the chassis cover To remove the chassis cover see 0 To remove the chassis cover Step 3 Disconnect all the necessary cables 2 7 1 To remove the system fans Loosen the screws that secure the interposer board assembly support Remove the...

Страница 25: ...Figure 2 23 Removing the System Fan 2 7 2 To install the system fans Reverse the steps above to install the system fans When installing the system fan cage into the chassis the arrows on the system fan cage must point to the direction of power supplies When installing the system fans recommend to install them in the order of system fan 1 and system fan 12 from left to right 22 ...

Страница 26: ...Appendix Appendix ...

Страница 27: ...Appendix Appendix A Support ...

Страница 28: ...rack cable connections Unplug the power cord and wait one minute Then reconnect the power cord and try again Remove all added options one at a time and try to power up the system If after removing an option the server works you may find that it is a problem with the option or a configuration problem between the option and the server Contact the option vendor for assistance If the system doesn t po...

Страница 29: ...ncy and the SIM boards you have Verify that the power supply has the capacity to power all the devices used in your system Ensure the power cord is firmly connected to the power supply and the ACoutlet If the power supply or the AC outlet has an on off switch make sure that it ison Cable Issues No boot situations can be caused by any of the following cabling issues Make sure the drive ribbon cable...

Страница 30: ...bed or loosened when you added the new drive Examples of troubleshooting system boot issues Below are some examples on how to troubleshoot system boot issues Fans don t spin when power button pressed Is at least one power supply fan spinning If it is yes there is good power to the modules Verify all required power cables are correctly plugged into the SIM boards Verify back panel cables are fully ...

Страница 31: ......

Страница 32: ...Appendix Appendix C China RoHS Regulations Figure I China RoHS Regulations ...

Отзывы: