22
M-4206
9) CONTROL CODES
Allows code selection listed in
Programmer’s manual.
Possible Values:
*
(
STD) Standard Codes
(ALT) Alternate Codes
10) CONT FORM LENGTH
Sets the page (label) size when the
‘SENSOR TYPE’
is set to
continuous
media
.
Possible Values:
Range: 0 – 9999; default = *100
(Units = .01 inch)
11) OOS MAXVOLT
Sets the media sensor level for the
Out Of Stock condition.
Possible Values:
Range: 0 – 16; nominal = *2
(Units = .1 volt)
12) TOF GAIN
Sets media sensor Top of Form gain
value.
Possible Values:
Range: 0 – 15; nominal = *10
13) TOF DELTA
Sets the minimum media sensor
change required to signify a label
gap or mark.
Possible Values:
Range: 0 – 50; nominal = *10
(Units = .1 volt)
14) TOF LOW
Sets the minimum media sensor reading
for paper (gap/notch) or mark
(reflective).
Possible Values:
Range: 0 – 50; nominal = *0
(Units = 0.1 volt)
15) LABEL WIDTH
Sets the label width.
Possible Values:
Range: 75 – 426; default = *426
(Units = .01 inch)
16) SCALABLE FONT
Sets the number of memory blocks to
allocate for scalable fonts.
Possible Values:
Range: 0 – 128; default = *64
(Units = 4K Bytes)
17) INTERNAL MODULE
Sets the number of memory blocks to
allocate for the internal RAM
module.
Possible Values:
Range: 0 – 128; default = *128
(Units = 4K Bytes)
18) LABEL ALIGNMENT
Sets the label alignment method
(see
Section 4.6)
.
Possible Values:
YES (user manually determines
‘ALIGN LENGTH’)
AUTO (printer determines ‘ALIGN
LENGTH’)
* NO (no Label Alignment used)
Содержание M-Class Mark II M-4206
Страница 1: ...M 4206 Operator s Manual ...
Страница 10: ...4 M 4206 ...
Страница 58: ...52 M 4206 ...
Страница 76: ...70 M 4206 ...