A-Class
83
Step
Action
Displayed Message
Comment
Q
Press and hold the FEED
Key until at least one label
has been output.
READY
The printer is ready for
use.
;
If the calibration
attempt fails, try
desensitizing the sensor
as follows:
Go to MEDIA SETTINGS
/ SENSOR
CALIBRATION /
ADVANCED ENTRY /
SENSOR GAIN and
lower the corresponding
GAIN SETTING by one.
Exit the menu, saving
the changes. Test the
media at the new
setting and if necessary
repeat until a usable
GAIN SETTING is
obtained.
5.3 Printhead Adjustments
To ensure consistent print quality over the wide range of media types and sizes, the printer
is equipped with a Leveling Cam and a Burn Line adjustment.
5.3.1 Leveling Cam Adjustment
When using media sizes that are less than full width of the printhead, adjust the Leveling
Cam for even pressure distribution, as follows:
;
If changing media sizes, readjust the Leveling Cam.
1. With the media loaded and the Head Lift Lever locked down, send a label format (or use
a Test format, see Section 4.3). Input a small quantity then begin printing.
Содержание A-Class A-4212
Страница 1: ...Operator s Manual ...
Страница 2: ......
Страница 5: ......
Страница 6: ......
Страница 8: ......
Страница 14: ...vi ...
Страница 20: ...6 A Class 1 2 1 Right Hand Models 1 2 3 4 6 7 8 9 5 27 28 15 16 17 18 19 14 20 21 10 11 12 13 3 22 23 24 25 26 ...
Страница 21: ...A Class 7 1 2 2 Left Hand Models 1 2 3 6 7 8 9 5 4 27 28 15 16 17 18 19 14 20 21 10 11 12 13 22 23 24 25 26 ...
Страница 22: ...8 A Class ...
Страница 84: ...70 A Class ...
Страница 128: ...114 A Class ...
Страница 136: ...122 A Class ...
Страница 140: ...126 A Class ...
Страница 144: ...130 A Class ...
Страница 158: ...144 A Class ...
Страница 160: ...146 A Class ...
Страница 166: ...152 A Class ...