www.datamax-oneil.com
27
Calibrate the Presenter Sensor:
After calibration is complete, the presenter sensor will be disabled. You must re-enable the presenter
before use.
1) Install the media in the printer
and route the liner through the
peeler door, see Section 2.3.1.
When the “FEED” key is
pressed, the label will be
peeled and presented for the
operator.
2) Click on the “Sensor
Calibration” printer component.
3) Click the “Presenter Sensor”
button to start the calibration
process.
Follow the instructions on the
following screen.
4) Type the number 6 as the
Advance Distance after
QMark/Gap. Click the “OK”
button.
This value may vary if
Datamax-O’Neil media is not
used and may require
adjustments to the Advance
Distance after QMark/Gap
parameter for the sensor to
work properly.
5) The following screen will be
shown. Click the “OK” button to
start the process.
After the calibration is
performed successfully, the
following confirmation screen
will be shown. If the sensor
calibration fails, repeat the
process.
312
Media Backing
Peeler Door
NOTE: To test the proper operation of the printer, press the “Feed” button. The label is separated from
the liner and a message “REMOVE LABEL” is shown in the LCD. After the label is removed, the printer will
print the next label.