73
Battery selection and management
This section refers exclusively to rechargeable, lead-acid batteries, for example car, tractor, truck, marine or
specialist deep-cycle batteries.
The size of battery you select will depend on the model of energizer you have and the Selector switch
position you use most frequently. Refer to
Operation
on page 70 for an explanation of the function of the
Selector switch.
Battery selection
As a guide, the amp hour (Ah) rating of the 12 V lead-acid battery required for each model is shown below.
This table is based on a 21 day operating period between battery charging. Although operating time can
exceed 21 days, this is likely to reduce the life of the battery and necessitate frequent replacement of the
battery. For a description of how the energizer prolongs the battery life, see
Battery Preservation
below.
For best system reliability and long term battery life, the preferred battery and charging regime is to use a
deep-cycle, lead-acid battery and to recharge it when it has discharged to about half-way. For more
information on testing battery charge level, see
Battery test setting
on page 72.
Energizer model
Selector switch position
Current required
Battery capacity
1 J model
Full Energy
Half Energy
110 mA
60 mA
110 Ah
60 Ah
2 J model
Full Energy
Half Energy
210 mA
105 mA
210 Ah
105 Ah
3 J model
Full Energy
Half Energy
340 mA
165 mA
340 Ah
165 Ah
Battery management
WARNING!
Batteries contain harmful chemicals and when used incorrectly, may cause injury. Observe
the guidelines for battery care, maintenance and safety in this manual and in the documentation
supplied with your battery.
Battery preservation
In order to extend the operating period between battery charges, the energizer will begin to operate at a
slow speed and half output energy when the battery capacity drops below approximately 40%.
In order to prevent deep discharge and thus irreversible damage to the battery, the energizer will stop
producing output pulses when the battery capacity drops below approximately 20%.
Содержание 1000/X1/401