
110
In the panel Programmer internal speaker sound settings is possible to set sound options
for some programmers with built-in internal speaker. Sound beeps are then generated from
internal programmer speaker after each device operation for indicating device operation result
– good or bad result.
Errors
This option allows to set a device verify errors saving to file. When verify errors occur, first 45
differences are written to Log window. If user wants to save the verify errors (data differences)
to file, he can set options in section Save device verify errors to file to one of two methods:
cumulate errors from all verify actions to the same file or save errors to file just from last verify
action. Verify errors will be saved to file with name specified by Error file name edit box.
Following error report file options are available:
option No (default)
verify errors saving to file is disabled. Errors are displayed just on
screen
option New
save verify errors to file just from last verify action. Before first write of
new verify action is file deleted and created as new one
option Append
verify errors from all verify actions are cumulated into the same file. If
file does not exist, the new file will be created
Box Error report file size limit contains settings that allow setting max. number of verify
errors saved to file. It contains following options:
Check box Stop verification after max. number of errors reached
If checked, verify action will finish after Max. number of errors will be written in file.
If not checked, all verify errors are saved to the file.
Edit box Max. number of errors specifies number of verify errors, that can be written to error
file in one verify operation.
Log file
This options associates with using of Log window. All reports for Log window can be written
into the Log file too. The Log file name is "Report.rep" as default. The control program creates
this file with name and directory specified in Log file name edit box.
Following Log file options are available:
No
default, content of Log window is not copied to Log file, i.e. all reports will be
displayed to Log window only
New
deletes old Log file and creates new one during each start of control program
Append adds Log window reports into existing Log file, If file does not exist, the new file will
be created
Checkbox Add date information to Log file name allows user to set date information into
Log file name specified by user in Log file name edit box. When the checkbox is checked,
program automatically adds current date string into user specified Log file name by the
following rules:
If user specified log file name has format:
<user_log_file_name>.<log_file_extension>
The name with added date will be:
<user_log_file_name><-yyyy-mmm-dd>.<log_file_extension>
The new part representing of date consists of yyyy - year, mmm - month and dd - day.
Содержание 448PRO2AP-AU
Страница 6: ...6 Introduction...
Страница 11: ...DATAMAN 448PRO2AP AU 11 DATAMAN 448PRO2AP AU...
Страница 19: ...DATAMAN 448PRO2AP 19 DATAMAN 448PRO2AP...
Страница 26: ...26 DATAMAN 48PRO2AP...
Страница 33: ...Setup 33 Setup...
Страница 38: ...38 Step 8 Installation process will start Step 9 Click Finish button to finish setup...
Страница 56: ...56 PG4UW...
Страница 123: ...PG4UWMC 123 PG4UWMC...
Страница 136: ...136 Installation procedure customized...
Страница 145: ...Common notes 145 Common notes...
Страница 157: ...Troubleshooting and warranty 157 Troubleshooting and warranty...