7
USER INTERFACE AND DIAGNOSTICS
USER INTERFACE
Receiver
Emitter
In the bottom side of the light curtain a user interface with 8 LEDs helps customer to check the status of the light curtain
and the POWERLINK / openSAFETY variation.
Receiver (RX):
LED
COLOR
FUNCTION NORMAL OPERATION
FUNCTION ERROR
Red/Green
BEAM STATUS
Red ON
►
At least one beam intercepted
Green ON
►
All beams free
Red ON
Yellow
SYNC BEAM
ON
►
First beam intercepted or not aligned
Blinking
uP ERROR
OPTIC ERROR
openSAFETY ERROR
Yellow
LAST BEAM
ON
►
Last beam intercepted or not aligned
M
Red
MASTER uP STATUS
OFF
►
Normal operation
Blinking
►
ON
►
Error ON uP MASTER
Boot Pre-op
S
Red
SLAVE uP STATUS
see LED S
ON
►
Error ON uP SLAVE
P
Red/Green
ETHERNET POWERLINK STATUS
Green ON
►
normal operation
Green blinking: pre-op
Green double-blinking: Firmware Update in
progress
Red ON
►
Ethernet Powerlink
Error
1
Green
EPL PORT 1 LINK
ON
►
there is a link
Blinking
►
there is activity on this link
no error indicator
2
Green
EPL PORT 2 LINK
ON
►
there is a link
Blinking
►
there is activity on this link
no error indicator
Emitter (TX):
LED
COLOR
FUNCTION NORMAL OPERATION
FUNCTION ERROR
Green
POWER
Green ON
►
Power ON, Normal Operation
Red ON
U
Yellow -
Blinking
Yellow
EMISSION
ON
►
Emission active
OPTIC ERROR
U uP ERROR
U
openSAFETY ERROR