Safety light curtains with infrared beams 

QUICK GUIDE 

 

 

This Quick Reference Guide does not replace the Instruction Manual. Download 
the Instruction Manual by reading the QR code here or at: www.datalogic.com. 
Click on 

Support

 > 

Search by product

 and enter the SG4 family name, then 

select your product from the dropdown list. Click on the 

Manuals & Technical 

Literature

 link to download your Instruction Manual. The Instruction Manual must 

be available at all times when installing and working with the product.

 

 

 

SAFETY INFORMATION 

 

The following points must be observed for a correct and safe use of the safety light curtains of the SG4 
FIELDBUS series: 

 

 The stopping system of the machine must be electrically controlled. 

 This control system must be able to stop the dangerous movement of the machine within the total machine stopping 

time T as per cfr. 1.3 of the Instruction Manual

 

and during all working cycle phases. 

 Mounting and connection of the safety light curtain must be carried out only by qualified personnel, according to the 

indications included in the special sections (refer to cfr. 2; 3; 4; 5) and in respect to the applicable Standards. 

 The safety light curtain must be securely installed so that access to the dangerous zone is not possible without 

interrupting the beams. 

 The personnel operating in the dangerous area must be well-trained and must have adequate knowledge of all the 

operating procedures of the safety light curtain. 

 Please carefully read the instructions for the correct functioning before powering the light curtain. 

 

Precautions to be observed for the choice and installation of the device 

 

 

Make sure that the protection level assured by the SG4 device (Type 4) is compatible with the real danger 
level of the machine to be controlled, according to EN ISO 13849-1 and EN 62061. 

 

 The dimension of the smallest object to be detected must be larger than the resolution level of the device. 

 The ESPE must be installed in a room complying with the technical characteristics indicated in cfr. “

Technical data

” of 

the Instruction Manual. 

 Do not place the device near intense and/or flashing light sources and, in particular, close to receiving unit front surface. 

 The presence of intense electromagnetic disturbances could jeopardise device operation. This condition has to carefully 

evaluated with the support of the Datalogic Technical service. 

 The operating distance of the device can be reduced in presence of smog, fog or airborne dust. 

 A sudden change in environment temperature, with very low minimum peaks, can generate a small condensation layer 

on the lenses and so jeopardise functioning. 

 Reflecting surfaces near the safety light curtain light beam (above, under or lateral) can cause passive reflections that 

can jeopardise functioning. 

 The safety device must be installed at a distance which is major or equal to the 

minimum safety distance S

 to ensure 

that the operator can not reach the dangerous area until the moving dangerous object has been blocked by the ESPE. 

 

 

The failure to respect the safety distance reduces or cancels ESPE the protection function. For more detailed 
information about calculation of safety distance, please refer to the Instruction Manual. 

Содержание SG4 FIELDBUS Series

Страница 1: ...ns for the correct functioning before powering the light curtain Precautions to be observed for the choice and installation of the device Make sure that the protection level assured by the SG4 device...

Страница 2: ...CONNECTOR 1 24VDC BROWN 2 NOT USED WHITE 3 0 VDC BLUE 4 NOT USED BLACK CN2 SIGNAL ETHERNET POWERLINK PORT1 1 TxD transmit data 2 RxD receive data 3 TxD transmit data 4 RxD receive data CN3 SIGNAL ETH...

Страница 3: ...dard installation described hereinafter is the one shown in figure with the bar assembled with the connectors pointing down Two yellow LEDs LAST SYNC on receiver unit facilitate the alignment procedur...

Страница 4: ...ly using brackets Verify that the green LED on the RX unit is ON and beams are not interrupted then verify that the red LED turns ON if even one single beam is interrupted condition where an object ha...

Страница 5: ...OP B xosdd Advanced up to 600mm SG4 xx xxx OP A 150 600 FFFF000D SG4 14_30 15_60 OP A xdd SG4 14_30 15_60 OP A xosdd Advanced from 750mm to 1800mm SG4 xx xxx OP A 750 1800 FFFF000D SG4 14_30 75_180 OP...

Страница 6: ...click on SG4 FIELDBUS device and select Change node number set the address from 1 to 240 Select EPL device address in AutomationStudio On device choose same address by setting the two rotary switches...

Страница 7: ...ot aligned M Red MASTER uP STATUS OFF Normal operation Blinking ON Error ON uP MASTER Boot Pre op S Red SLAVE uP STATUS see LED S ON Error ON uP SLAVE P Red Green ETHERNET POWERLINK STATUS Green ON no...

Страница 8: ...t regarding the final installation Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measure...

Отзывы: