SG-PSB INSTRUCTION MANUAL
7
ADJUSTMENT
ADJUSTING THE VERTICAL AXIS AND THE ANGULAR POSITION OF
THE PLATES
Fasten the plate to the floor in the desired rough angular position, according to the positions
established by the reference grooves (main angles: 0° - 45° - 90° for each quadrant); to do
this, use the 3 slots on the bottom plate and M10 screws. Do not tighten the M10 screws
completely. Unfasten the lock nuts on the dowels, then use the dowels to adjust the
inclination; during this operation, use the spheric level as a reference. Once the desired
inclination is obtained, tighten the screws to the floor. If necessary, proceed to a further
adjustment by rotating the moulded plate to the desired position, then tighten the lock nuts on
the dowels (Fig. 8).
Fig. 8
Slots for floor screws
Spheric level