2
CONNECTIONS
RECEIVER (RX)
EMITTER (TX)
OVERRIDE2
7
2
10
3
4
8
9
1
11
6
12
5
+24 Vdc
OSSD1
LAMP INPUT
MUTING
ENABLE
OVERRIDE1
0 V
OSSD2
OVERRIDE STATUS
EDM
+24 Vdc
N.C. external contact
EARTH
N.C.
RESET / RESTART/
RESTART MODE
0 V / 24 V (*)
Error! Objects cannot be created from editing field
codes.
Error! Objects cannot be created from editing field
codes.
Error! Objects cannot be created from editing field
codes.
M12 12 Poles:
1 = brown = +24Vdc
2 = blue
= 0V
3 = white = RESET/RESTART /RESTART MODE (*)
4 = green = OVERRIDE1
5 = pink
= OSSD2
6 = yellow = EDM
7 = black = MUTING ENABLE
8 = grey
= OSSD1
9 = red
= OVERRIDE2
10 = violet = LAMP INPUT
11 = grey/pink =
OVERRIDE STATUS
12 = red/blue =
EARTH
M12 5 Poles:
1 = brown = +24
Vdc
2 = white = MUTING2
3 = blue = 0V
4 = black =
MUTING1
5 = grey
= NOT USED
M12 5 Poles:
1 = brown = +24 Vdc
2 = white
= TEST
3 = blue
= 0V
4 = black
= EARTH
5 = grey
= NOT USED
M12 5 Poles:
1 = brown = +24 Vdc
2 = white
= NOT USED
3 = blue
= 0V
4 = black
= NOT USED
5 = grey
= NOT USED
(*) Connected to 24V
Automatic RESTART
NC: RESET function
Connected to 0V
Manual RESTART
NC: RESET/RESTART function