background image

Using the Quickscan™ QM21X1

Quick Reference Guide

9

Using the Quickscan™ QM21X1

Bar Code Reading 

Point the reader at the target and pull the trigger to enable 
the illuminator (red beam) to decode the bar code label. The 
illuminator will remain on until the symbol is decoded.
When scanning a bar code label, you can adjust the distance 
or angle to the label to help facilitate reading.

Aim and Scan

012345

012345

65°

65°

Содержание QuickScan I QM21X1

Страница 1: ...QuickScan QM21X1 General Purpose Handheld Linear Imager Bar Code Reader with Datalogic s STAR Cordless System Quick Reference Guide...

Страница 2: ...uld future revisions of this manual be published you can acquire printed versions by contacting your Datalogic representa tive Electronic versions may either be downloadable from the Datalogic website...

Страница 3: ...ng the Reader 10 Link Datalogic RF Devices to Base 10 Power Off 10 Programming 10 Using Programming Bar Codes 11 Configure Other Settings 11 Resetting Standard Product Defaults 11 Selecting the Base I...

Страница 4: ...ii QuickScan QM24XX Ergonomic Recommendations 36 Cleaning 37 Services and Support 38...

Страница 5: ...t the receiving party can establish was 1 in the public domain 2 already in the receiving party s possession or rightfully known prior to receipt 3 rightfully learned from a third party not in violati...

Страница 6: ...five 5 years after the termination of this Agreement 6 Limited Warranty 6 1 Datalogic warrants that under normal use and operation the Datalogic Prod uct will conform substantially to the applicable...

Страница 7: ...E POS SIBILITY OF SUCH DAMAGES 9 Government Restricted Rights International Use 9 1 Use duplication or disclosure of the Software by the U S Government is sub ject to the restrictions for computer sof...

Страница 8: ...atalogic shall have the right at its absolute dis cretion to initiate proceedings in the courts of any other state country or ter ritory in which End User resides or in which any of End User s assets...

Страница 9: ...h its host 1 Configure the Base Station starting on page 3 2 Charge the Batteries see page 7 3 Link to the Base Station see page 10 4 Select the Interface Type see page 12 5 Configure the Reader start...

Страница 10: ...locking mechanism to ensure electrical contact between Reader and Base in case of inad vertent movements To Lock the Reader in the Base 1 Insert the Reader into the Base The lock lever rests in its n...

Страница 11: ...apply ing power to the Base Station NOTE it is good practice to put the scanner in the locked condition at the end of the working shift or when not in use for an extended period of time This will ens...

Страница 12: ...se Station 2 Securely plug the Power Cable if used and Interface I F Cable connectors into their respective ports in the underside of the Base Station 3 After the cables are plugged in reinsert the ru...

Страница 13: ...nterface cables have a Y con nection where its female end mates with the male end of the cable from the keyboard and the remaining end at the key board port on the terminal PC Figure 4 Connecting to t...

Страница 14: ...adle and Host Figure 5 Reader Layout Using the BC20XX Radio Base Radio Base LEDs LEDs on the QuickScan Base provide information about the Base as well as battery charging status as shown in Figure 6 F...

Страница 15: ...reader directly to a host through the micro USB connector available in the bottom of the handle as shown LED STATUS Power on Data Yellow On Base is powered Yellow Blinking Base receives data and comm...

Страница 16: ...he contact springs 2 Extract the battery pack by slightly rotating the pack and pulling away from the reader To mount the new battery pack reverse the process 1 Insert the top of the new pack inside t...

Страница 17: ...reader at the target and pull the trigger to enable the illuminator red beam to decode the bar code label The illuminator will remain on until the symbol is decoded When scanning a bar code label you...

Страница 18: ...code below to shut off power to the handheld until the next trigger pull PowerOff Programming The reader is factory configured with a set of standard default features After scanning the interface bar...

Страница 19: ...ration Configure Other Settings Additional programming bar codes are available in the PRG to allow for customizing programming features If your installa tion requires different programming than the st...

Страница 20: ...information associated with each interface proceed to the corresponding chapter in the Quick Scan Q21XX PRG Configuring the Interface Scan the programming bar code which selects the appropriate interf...

Страница 21: ...RS232 STD RS 232 Wincor Nixdorf Select RS232 WN RS 232 for use with OPOS UPOS JavaPOS Select RS 232 OPOS USB COM to simulate RS 232 standard interface Select USB COM STDa a Download the correct USB C...

Страница 22: ...PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Standard Key Encoding Select KBD AT Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard Select KBD AT NK AT PS 2 25 286 3...

Страница 23: ...KBD XT Keyboard Wedge for IBM Terminal 3153 Select KBD IBM 3153 Keyboard Wedge for IBM Terminals 31xx 32xx 34xx 37xx make only keyboard Select KBD IBM M Keyboard Wedge for IBM Terminals 31xx 32xx 34xx...

Страница 24: ...out alternate key encoding AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Std Key Encoding Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard AT PS 2 25 286 30 286 5...

Страница 25: ...lowing Country Modes U S Belgium Britain France Germany Italy Spain Sweden COUNTRY MODE ENTER EXIT PROGRAMMING MODE Country Mode U S Country Mode Belgium Country Mode Britain Country Mode Croatia Coun...

Страница 26: ...Scan QM21X1 COUNTRY MODE continued Country Mode Denmark Country Mode France Country Mode French Canadian Country Mode Germany Country Mode Hungary Country Mode Italy Supports only the interfaces liste...

Страница 27: ...COUNTRY MODE continued Country Mode Japanese 106 key Country Mode Lithuanian Country Mode Norway Country Mode Poland Country Mode Portugal Country Mode Romania Country Mode Slovakia Supports only the...

Страница 28: ...g the Base Interface Type 20 QuickScan QM21X1 COUNTRY MODE continued Country Mode Spain Country Mode Sweden Country Mode Switzerland Supports only the interfaces listed in the Country Mode feature des...

Страница 29: ...ormat in which the reader sends character data This applies to keyboard wedge interfaces This does not apply when an alternate key encoding keyboard is selected CAPS LOCK STATE ENTER EXIT PROGRAMMING...

Страница 30: ...specifies the setting of the Numbers Lock Num lock key while in keyboard wedge interface This only applies to alternate key encoding interfaces It does not apply to USB keyboard NUMLOCK ENTER EXIT PR...

Страница 31: ...a good read green spot Use the bar codes below to specify the duration of the good read pointer beam after a good read GOOD READ GREEN SPOT DURATION ENTER EXIT PROGRAMMING MODE Green Spot Duration Dis...

Страница 32: ...released scanning is activated until programmable duration1 has elapsed or the trigger has been pulled again to transition to another state Double Read Timeout1 prevents undesired multiple reads whil...

Страница 33: ...an Modes Quick Reference Guide 25 SCAN MODE Scan Mode Trigger Single Scan Mode Trigger Hold Multiple Scan Mode Trigger Pulse Multiple Scan Mode Flashing Scan Mode Always On Scan Mode Stand Mode CSNRM0...

Страница 34: ...6 7 ounces 190 g Cradle 7 6 ounces 215 g Electrical Characteristics Battery Type Lithium Ion 1400 mAh Typical charge time for full charge from full dis charge 6 hours with Host Power through the micro...

Страница 35: ...actory default configuration c Based on ISO 15423 specifications Depth of Field Typical a a Minimum distance determinedby symbol length andscanangle Printing resolution contrast and ambient light depe...

Страница 36: ...ZN Plessey Anker Plessey Follet 2 of 5 GS1 DataBar Omnidirectional GS1 DataBar Limited GS1 DataBar Expanded GS1 DataBar Truncated DATABAR Expanded Cou pon Interfaces Supporteda RS 232 Std RS 232 Winco...

Страница 37: ...29 IP42 scanner only ESD Level Air Discharge 16 kV a See Interface Selection on page 12 for a listing of available interface sets by version type Regulatory Electrical Safety UL 60950 CSA C22 2 No 609...

Страница 38: ...highest frequency and volume upon power up Good Read Beep A label has been successfully scanned by the reader LED behavior for this indication is configurable via thefeature Good Read When to Indicat...

Страница 39: ...Label A label has been rejected N A Reader sounds three times at lowest fre quency and cur rent volume Label Program ming Mode Accep tance of Partial Label In cases where multiple labels must be scan...

Страница 40: ...Configuration Contact Helpdesk for assis tance 2 Interface PCB 6 Digital PCB 12 Imager Indication LEDs Power up Complete Yellow LED on Reader Disabled by the HOST or the communication with HOST is not...

Страница 41: ...parts components subassemblies or products that have been tested as meeting applicable specifications for equivalent new material and products Customer will allow Datalogic to scrap all parts removed...

Страница 42: ...than Datalogic service personnel or its authorized representatives ii any claimed defect failure or damage which Datalogic determines was caused by faulty operations improper use abuse misuse wear and...

Страница 43: ...ABOVE THE REMEDY SET FORTH IN THIS WARRANTY STATE MENT IS THE CUSTOMER S SOLE AND EXCLUSIVE REMEDY FOR WARRANTY CLAIMS UNDER NO CIRCUMSTANCES WILL DATALOGIC BE LIABLE TO CUSTOMER OR ANY THIRD PARTY F...

Страница 44: ...correct heights Reduce or eliminate vibration Reduce or eliminate direct pressure Provide adjustable workstations Provide adequate clearance Provide a suitable working environment Improve work proced...

Страница 45: ...e a good con nection Use a soft dry cloth to clean the product If the product is very soiled clean it with a soft cloth moistened with a diluted non aggressive cleaning solution or diluted ethyl alcoh...

Страница 46: ...Aladdin a multi platform utility pro gram that allows device configuration using a PC It provides RS 232 interface configuration as well as bar code printing Service Support Technical Support Product...

Страница 47: ......

Страница 48: ...and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U Datalogic ADC Inc 959 Terry Street Eugene OR 97402 USA Telephone 1 541 683 5700 Fa...

Отзывы: