Product Reference Guide
311
User Environment
Operating Tem-
perature
32° to 122° F (0° to 50° C)
Charging
Temperature
32° to 104° F (0° to 40° C)
Storage Tem-
perature
-4° to 158° F (-20° to 70° C)
Humidity
5% to 90% relative humidity, non-condensing
5% to 90% relative humidity, non-condensing
Drop Specifica-
tions
Scanner withstands 18 drops from 1.5 m
(4.9 feet) to concrete
Ambient Light
Immunity
Up to 120,000 Lux
Contaminants
Spray/rain
Dust/particu-
lates
IEC 529-IP42 (scanner only)
ESD Level
16 KV
QM21X1
QBT21X1
Regulatory
Electrical Safety
UL 60950, CSA C22.2 No. 60950, IEC 60950
EMI/RFI
Europe; Russia; Australia; China;
Singapore; Mexico
Europe; Australia; Russia; USA/CAN-
ADA; Japan; Mexico; South Korea;
Brazil; Argentina; China; Singapore;
Taiwan
Radio Features
Frequency Range
433MHz
2400 to 2483.5 MHz
Range (in open
air)
25 m (typical)
Item
QM/QBT21X1
Содержание QuickScan I QM2131
Страница 62: ...Enter Exit Programming Mode USB Keyboard Speed 52 QuickScan I QM21X1 QBT21X1 NOTES...
Страница 98: ...Enter Exit Programming Mode Green Spot Duration 88 QuickScan I QM21X1 QBT21X1 NOTES...
Страница 264: ...Symbologies 254 QuickScan I QM21X1 QBT21X1 NOTES...
Страница 284: ...Enter Exit Programming Mode 274 QuickScan I QM21X1 QBT21X1 NOTES...
Страница 324: ...314 QuickScan I QM21X1 QBT21X1 NOTES...
Страница 340: ...330 QuickScan I QM21X1 QBT21X1 NOTES...
Страница 342: ...332 QuickScan I QM21X1 QBT21X1 Interleaved 2 of 5 Code 32 Codabar Code 93 Code 11 12345678901231...
Страница 344: ...334 QuickScan I QM21X1 QBT21X1 NOTES...
Страница 346: ...336 QuickScan I QM21X1 QBT21X1 5 6 7 8 9...
Страница 347: ...Product Reference Guide 337 A B C D E F...
Страница 348: ...338 QuickScan I QM21X1 QBT21X1 NOTES...