PM/PBT9600 TECHNICAL SPECIFICATIONS
PRODUCT REFERENCE GUIDE
349
ENVIRONMENTAL CHARACTERISTICS
Operating Temperature
-20° to 50° C (-4° to 122° F)
Recharging Temperature
a
a. NOTE: The higher the ambient temperature, the longer the charging time.
Recommended 0° to 35° C (32° to 95° F)
Max allowed 0° to 40° C (32° to 104° F)
Storage Temperature
-40° to 70° C (-40° to 158° F)
Humidity
0 to 95% non-condensing
Drop Resistance
Withstands 50 drops from 2.4 m/8 ft @20° C;
Withstands 50 drops from 2.0 m/6.6 ft @-20° C
Ambient Light Immunity
100,000 Lux
Water/Dust Protection
Degree
IP67 and IP65
ESD Protection
20 KV
ESD: Opening the battery door allows access to electrostatic sensitive
areas. In particular, when connecting and using the micro-USB cable, it
is recommended to operate in an environment with low levels of elec
-
trostatic charge (e.g. office) and avoiding the introduction of fingers or
objects into the battery compartment.
RADIO CHARACTERISTICS
Star 433 models
Star 910 models
BT models
Frequency
working center
433MHZ
910MHZ
2400 to 2483.5 MHz
Programmable Speed
19.2 kb/s
500 kb/s (default)
36.8 kb/s
500 kb/s (default)
Typical Range
(in open air)
100 m (at 500 kb/s)
150 m (at 19.2 kb/s)
180 m (at 500 kb/s)
230 m (at 36.8 kb/s,
frequency hopping)
80 m (at 36.8 kb/s,
fixed channel)
100 m
Max number of devices
per base station
16
7
NOTE: A radio coverage reduction is expected when the base station is
charging a gun.
Содержание PowerScan Series
Страница 100: ...84 POWERSCAN PD PM PBT9600 CONFIGURATION USB OEM INTERFACE SECTION CONTENTS USB OEM Device Usage...
Страница 399: ...SAMPLE BARCODES PRODUCT REFERENCE GUIDE 383 Interleaved 2 of 5 Code 32 Codabar Code 93 Code 11 12345678901231...
Страница 402: ...SAMPLE BARCODES 386 POWERSCAN PD PM PBT9600 2D Barcodes continued QR Code 35900G9 Micro QR Code 123456 UCC Composite...
Страница 404: ...KEYPAD 388 POWERSCAN PD PM PBT9600 1 2 3 4 5 6 7 8 9 CANCEL...