Datalogic ADC, Inc.
959 Terry StreetEugene, OR 97402USATelephone: (541) 683-5700Fax: (541) 345-7140
©2013 Datalogic ADC, Inc.
820045614 (Rev A)
January 2013
www.datalogic.com
Страница 1: ...PowerScan PD9530 Industrial Corded Handheld Area Imager Bar Code Reader Quick Reference Guide...
Страница 2: ...tative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appro priate media If you visit our website and would like to make comments or sugges...
Страница 3: ...gure Other Settings 19 Resetting Product Defaults 19 Reading Parameters 20 Good Read Green Spot Duration 20 Operating Modes 21 Scan Mode 21 Motion Aiming Control 22 Pick Mode 23 Multiple Label Reading...
Страница 4: ...NOTES...
Страница 5: ...e any information that the receiv ing party can establish was 1 in the public domain 2 already in the receiving party s possession or rightfully known prior to receipt 3 rightfully learned from a thir...
Страница 6: ...ll take steps to protect the Proprietary Information no less securely than if it were End User s own intellectual property 5 3 The provisions of this Proprietary Information Section shall survive and...
Страница 7: ...BE LIABLE TO END USER OR ANY THIRD PARTY FOR LOST PROFITS LOST DATA INTERRUPTION OF BUSINESS OR SERVICE OR FOR ANY OTHER SPECIAL CONSEQUENTIAL CONTINGENT INDIRECT INCIDENTAL PUNITIVE EXEMPLARY OR OTHE...
Страница 8: ...f End User s assets are located 11 5 Attorneys Fees In the event an action is brought to enforce the terms and condi tions of this Agreement the prevailing party shall be entitled to reasonable attor...
Страница 9: ...mdensity codes DPM laser ink jet and dot peen Omni directional Operating To read a symbol or capture an image you simply aim the reader and pull the trigger Since the PowerScan PD9530 is a powerful om...
Страница 10: ...owerScan PD9530 can also function as a camera by capturing entire images or image portions of labels signatures and other items Autoscanning An autoscan command causes the reader to scan continuously...
Страница 11: ...e Front marking on the Cable Holder is facing out with the arrow pointing towards the front of the scanner 4 Insert the end of the cable into the socket of the Cable Holder 5 Push the Cover along the...
Страница 12: ...will be small er when the reader is closer to the bar code and larger when it is farther from the code Symbologies with smaller bars or el ements mil size should be read closer to the unit Symbolo gi...
Страница 13: ...e type are provided in this section For defaults and additional infor mation associated with each interface proceed to the corre sponding chapter in the PowerScan PD9530 PRG Configuring the Interface...
Страница 14: ...d interface RS 232 RS 232 Wincor Nixdorf RS232 WN RS 232 for use with OPOS UPOS JavaPOS RS 232 OPOS USB USB Com to simulate RS 232 standard interface USB COMa USB OEM can be used for OPOS UPOS JavaPOS...
Страница 15: ...g the Interface Type Quick Reference Guide 11 USB continued USB Keyboard with standard key encoding USB KBD USB Keyboard with alternate key encoding USB KBD ALT USB Keyboard for Apple computers USB KB...
Страница 16: ...character emulation for keyboard interfaces Keyboard Interface KEYBOARD WEDGE IBM AT or PS 2 PCs Standard Key Encoding KBD AT IBM AT or PS 2 PCs Standard Key Encoding without external keyboard KBD AT...
Страница 17: ...ted by the keyboard This option is usable only with USB KBD and Keyboard Wedge interface without the Alternate Key mode COUNTRY MODE ENTER EXIT PROGRAMMING MODE Country Mode U S Country Mode Belgium C...
Страница 18: ...530 COUNTRY MODE Continued Country Mode Czech Country Mode Denmark Country Mode France Country Mode French Canadian Country Mode Germany Country Mode Hungary Supports only the interfaces listed in the...
Страница 19: ...Guide 15 COUNTRY MODE Continued Country Mode Italy Country Mode Japanese 106 key Country Mode Lithuanian Country Mode Norway Country Mode Poland Country Mode Portugal Supports only the interfaces lis...
Страница 20: ...e 16 PowerScan PD9530 COUNTRY MODE Continued Country Mode Romania Country Mode Spain Country Mode Sweden Country Mode Slovakia Country Mode Switzerland Supports only the interfaces listed in the Count...
Страница 21: ...the format in which the reader sends character data This applies to keyboard wedge interfaces This does not apply when an alternate key encoding keyboard is se lected ENTER EXIT PROGRAMMING MODE Caps...
Страница 22: ...on specifies the setting of the Numbers Lock Num lock key while in keyboard wedge interface This only applies to alternate key encoding interfaces It does not apply to USB keyboard ENTER EXIT PROGRAMM...
Страница 23: ...code once to enter Programming Mode scan the desired parameter settings scan the ENTER EXIT bar code again to accept your changes which exits Programming Mode and re turns the reader to normal operat...
Страница 24: ...uisition time and if no code is decoded will switch on again before the next acquisition The illuminator will remain on until the symbol is decoded As you read code symbols adjust the distance at whic...
Страница 25: ...ents undesired multiple reads while in this mode Trigger Hold Multiple When the trigger is pulled scanning starts and the product scans until the trigger is released or maximum scan on time 1 has elap...
Страница 26: ...ming system when motion is detected Scan the Enter Exit Programming bar code above then either of the barcodes below ENTER EXIT PROGRAMMING MODE Scan Mode Trigger Single Scan Mode Trigger Pulse Multip...
Страница 27: ...or transmitted to the host It is active only while the scanner is in Trigger Single mode If the scanner switches to a different Read Mode Pick Mode is automatically disabled Multiple Label Reading Th...
Страница 28: ...cable Electrical Characteristics Voltage Current PD9530 PD9530 HP PD9530 HPE PD9530 DPM InputVoltage 5VDC 5 10to30VDC 5VDC 5 InputCurrent Operating typical 335mA 135mA 10V 350mA Operating max 475mA 30...
Страница 29: ...ISBT128 Code39 Code39FullASCII Code39CIP Code32 Coda bar Interleaved2of5 IATA Industrial2of5 Standard2of5 Code11 MSI Plessey Code93 Follet2 5 2D Stacked Codes DataMatrix MaxiCodeandQRCodes QR MicroQR...
Страница 30: ...65 ESDLevel 20KV Beeper Speaker 80dB 10cm Regulatory ElectricalSafety UL60950 CSAC22 2No 60950 IEC60950 EMI RFI NorthAmerica FCC Part15ClassB Canada IC ICES 003ClassB Russia Gost EuropeanUnionEMCDirec...
Страница 31: ...sinthe processofpower ing up Readerbeepsfour timesathighestfre quencyandvolume uponpower up GoodRead Beep Alabelhasbeen successfully scannedbythe reader LEDbehaviorfor thisindicationis configurablevia...
Страница 32: ...labelhasbeenscanned LEDblinkscon tinuously Readersounds fourlowfre quencybeeps LabelProgram mingModeRejec tionofLabel Alabelhasbeen rejected N A Readersounds threetimesat lowestfre quencyandcur rentv...
Страница 33: ...sequence will be repeated Press and release the trig ger to hear the FRU indication code The following table describes the LED flashes beep codes as sociated with an error found LabelProgram mingModeC...
Страница 34: ...during scanning Use a soft dry cloth to clean the product If the product is very soiled clean it with a soft cloth moistened with a diluted non aggressive cleaning solution or diluted ethyl alcohol C...
Страница 35: ...t has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful inter...
Страница 36: ...s for radio noise emissions as described in the Radio Interference Regula tions of the Canadian Department of Communications Le present appareil numerique n emet pas de bruits radioelec triques depass...
Страница 37: ...um 900mA Imager Labeling Aiming System The PowerScan aiming system meets the Class 2 require ments for laser safety The laser information is located on the sides of the Scanner as shown below Sample l...
Страница 38: ...LE L OEIL NU ET IL EST MIS PAR LA FEN TRE D SIGN E SUR L ILLUSTRA TION DANS LA FIGURE ALUZL SERES VISIBLE AL OJO HUMANO Y ES EMITIDA POR LA VENTANA INDICADA EN LA FIGURA LUCE LASER NON FISSARE IL FASC...
Страница 39: ...ivi di installazione utilizzo o manutenzione Il prodotto utilizza un diodo laser a bassa potenza Sebbene non siano noti danni riportati dall occhio umano in seguito ad una esposizione di breve durata...
Страница 40: ...ITE LASER Ce produit est conforme aux normes de s curit laser en vi gueur sa date de fabrication CDRH 21 CFR 1040 et EN 60825 1 Il n est pas n cessaire d ouvrir l appareil pour l installation l utilis...
Страница 41: ...un diodo l ser a baja potencia No son noto rios da os a los ojos humanos a consecuencia de una ex posici n de corta duraci n Eviten de mirar fijo el rayo l ser as como evitar an cualquiera otra fuente...
Страница 42: ...w adc datalogic com German InformationenzurEntsorgung von Elektro undElektronik Altger ten WEEE erhalten Sie auf der Webseite www adc datalogic com Spanish Si desea informaci n acerca de los procedimi...
Страница 43: ...damage to orlossof configurations da ta and applications on the repaired units and at its sole discretion can return the units in the factory default configuration or with any software or firmware up...
Страница 44: ...er in violation of this provision shall be valid or binding upon Datalogic DATALOGIC S LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EX PRESS OR IMPLIED ORAL OR WRITTEN STATUTORY OR OTHERWISE IN...
Страница 45: ...page where you can download specific Manuals and Software Utilities including Datalogic Aladdin a multi platform utility program that allows device configuration using a PC It provides RS 232 interfac...
Страница 46: ...Services and Support 42 PowerScan PD9530 NOTES...
Страница 47: ...prechen Basadoenlaaproximaci ndelasleyesdelosPa sesMiembrosrespectoa lacompatibilidadelectro magn ticaylasMedidasdeseguridad relativasalproducto Questadichiarazione basata sullaconformit deiprodottial...
Страница 48: ...Datalogic ADC Inc 959 Terry Street Eugene OR 97402 USA Telephone 541 683 5700 Fax 541 345 7140 2013 Datalogic ADC Inc 820045614 Rev A January 2013 www datalogic com...