Technical Specifications
Quick Reference Guide
25
Depth of Field (Typical)
a
Symbology
Standard Model:
High Performance:
Code 39
4 mils: 6-17 cm
20 mils: 4-55 cm
40 mils: 4-85 cm
2.5 mils: 2-6 cm
20 mils: 3-70 cm
40 mils: 3-110 cm
EAN 13
13 mils: 4-48 cm
13 mils: 3-60 cm
PDF-417
10 mils: 2-25 cm
10 mils: 2-30 cm
DataMatrix
7.5 mils: 7-14 cm
10 mils: 4-18 cm
4mil: 2-6 cm
10mil: 2-20 cm
a.
13 mils DOF based on EAN. All other 1D codes are Code 39. All labels grade A,300 lux ambient light, 20°C,
label inclination 10°
Decode Capability
1D Bar Codes
GS1 Databar linear codes, UPC/EAN (A,E,13,8), UPC/EAN with P2/P5 Addons, UPC/EAN Cou-
pons, ISBN, Code128, EAN128, ISBT128, Code39, Code39 Full ASCII, Code39 CIP, Code 32, Coda-
bar, Interleaved 2 of 5, IATA, Industrial 2 of 5, Standard 2 of 5, Code11, MSI, Plessey, Code 93,
Follet 2/5
2D / Stacked Codes
DataMatrix, MaxiCode and QR Codes(QR, Micro QR and Multiple QR codes), Aztec
- Postal codes including:
Australian Post, China Post, Japanese Post, KIX Post, Planet Code, Postnet, Royal Mail
Code(RM45CC), IMB
- stacked codes including EAN/JAN Composites; GS1 Databar Composites, GS1 Databar
Expanded Stacked; GS1 DataBar Stacked; GS1 DataBar Stacked Omnidirectional; MacroPDF;
Micro PDF417; PDF417; UPC A/E Composites, French CIP13, Grid Matrix(Chinese) code
Interfaces Supported
RS-232, Keyboard Wedge, and USB.
See page 9 for a listing of available interface options.
User Environment
Operating Temperature
-4° to 122° F (-20° - +50° C )
Storage Temperature
-40° to 158° F (-40° to 70° C)
Humidity
0 to 95% non-condensing