REFERENCES
145
The message is sent in the following format:
"Message" CR LF
5.3.3
Reception Warning Message
The Master cradle can transmit warning messages to the Host regarding wrong
reception of data. Example:
/*Two-Ways Out of Sequence!(.....)*/
This message is transmitted to the Host by the Master cradle when the
Master cradle receives a closing string from the Host for a Two-way tx
communication, but this was either not open or already closed, therefore the
data will be lost. See par. 5.9.4.
5.3.4
Master Header/Terminator Selection
In addition to the standard header/terminator selection, the Master cradle can add its
own header/terminator to the entire message sent to the Host.
In the STAR-System™ network headers and terminators for all RF Devices are
disabled by default.
The Master header and terminator default values are as follows depending on the
interface selection towards the Host:
RS-232:
no header, terminator CR-LF
WEDGE:
no header, terminator ENTER
5.4 DATA FORMAT
For an overview of Message Formatting see Chapter 6.
5.4.1
Header/Terminator Selection
The header/terminator selection is not effected by the reading of the restore default
code. In fact, header and terminator default values depend on the interface selection:
RS-232:
no header, terminator CR-LF
WEDGE:
no header, terminator ENTER
Содержание PowerScan D8330
Страница 8: ......
Страница 13: ...INSTALLATION 5 2 3 RS 232 CONNECTION 2 4 USB if required...
Страница 14: ...POWERSCAN D8330 M8300 6 2 5 IBM USB POS if required...
Страница 15: ...INSTALLATION 7 2 6 WEDGE CONNECTION 2 7 PEN EMULATION CONNECTION...
Страница 211: ......