Enter Configuration
Exit and Save Configuration
Ì$+;Î
DATA FORMAT
Ì$-?Î
77
CHARACTER REPLACEMENT
disable character replacement
ÌEO0mÎ
This parameter allows up to three characters to be replaced from the barcode read. These
substitutions are stored in memory. To define each
character replacement:
Read one of the following character replacement codes:
first character replacement
ÌEO1pÎ
second character replacement
ÌEO2sÎ
third character replacement
ÌEO3vÎ
From the Code Identifier Table in Appendix
, read the Code Identifier for the desired
code family.
0
= character replacement will be effective for all code families.
From the Hex/Numeric Table read two characters corresponding to the Hex value
(
00
-
FE
), which identifies the character to be replaced. For Wedge and USB-KBD
interfaces, it is also possible to read the
Special Key(s)
From the Hex/Numeric Table read two characters corresponding to the Hex value
(
00
-
FE
), which identifies the new character to replace. For Wedge and USB-KBD
interfaces, it is also possible to read the
Special Key(s)
FF
= the character to be replaced will be substituted with no character, that is, it will be
removed from the code.
Содержание PowerScan D8300
Страница 2: ...PowerScan D8330 M8300 M8300 DK Reference Manual...
Страница 14: ...INSTALLATION 5 2 3 RS 232 CONNECTION 2 4 USB if required...
Страница 15: ...POWERSCAN D8330 M8300 M8300 DK 6 2 5 IBM USB POS if required...
Страница 16: ...INSTALLATION 7 2 6 WEDGE CONNECTION 2 7 PEN EMULATION CONNECTION...
Страница 244: ......