Technical Specifications
320
PowerScan™ PD9531-AR/PBT9501-AR/PM9501-AR
Error Codes
Upon startup, if the reader sounds a long tone, this means the reader has
not passed its automatic Selftest and has entered FRU (Field Replaceable
Unit) isolation mode. If the reader is reset, the sequence will be repeated.
Press and release the trigger to hear the FRU indication code.
The following table describes the LED flashes/beep codes associated with an
error found.
NUMBER OF
LED FLASHES/
BEEPS
Error
CORRECTIVE ACTION
1
Configuration
Contact Helpdesk for
assistance
2
Interface PCB
6
Digital PCB
11
Imager
Base Station Indications (Cordless Models ONLY)
Base Station Button Indicators
BUTTON PUSH
EVENT
CORDLESS
RED
INDICATOR(**)
GREEN
INDICATOR(**)
Push at power-up
force device connection
(Aladdin)
Off
Slow blink
Fast blink
< 5 sec
Paging
Off
Fast blink
5 to 10 sec
Unlink (Only Bluetooth)
Off
Slow blink
Programming Mode Indications (continued)
INDICATION
DESCRIPTION
LED
BEEPER
Label Program-
ming Mode Accep-
tance of
Programming
Configuration option(s)
have been successfully
programmed via labels
and the reader has exited
Programming Mode.
N/A
Reader sounds one
high frequency
beep and 4 low fre-
quency beeps fol-
lowed by reset
beeps.
Label Program-
ming Mode Cancel
Item Entry
Cancel label has been
scanned.
N/A
Reader sounds two
times at low fre-
quency and current
volume.
Содержание PowerScan 9501-AR Series
Страница 32: ...Setup 22 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 36: ...Configuration Using Bar Codes 26 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 92: ...Enter Exit Programming Mode 82 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 184: ...174 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 318: ...References 308 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 322: ...Message Formatting 312 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 360: ...Scancode Tables 350 PowerScan PD9531 AR PBT9501 AR PM9501 AR...