Enter/Exit Programming Mode
Product Reference Guide
157
GS1 DataBar™ Expanded Set Length 1
This feature specifies one of the bar code lengths for
. Length 1 is the minimum label length if in
Mode, or the first fixed length if in
Mode. Length
includes the bar code’s data characters only. The length can be set from 1
to 74 characters.
provides some examples for setting Length 1. See
detailed instructions on setting this feature.
Table 18. GS1 DataBar™ Expanded Length 1 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
01 Character
07 Characters
52 Characters
74 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT GS1 DataBar™ EXPANDED LENGTH 1SETTING
4
Scan Two Characters
From
‘0’ and ‘1’
‘0’ and ‘7’
‘5’ and ‘2’
‘7’ AND ‘4’
5
Scan ENTER/EXIT PROGRAMMING MODE
Select GS1 DataBar™ Expanded Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
DEFAULT
01 = Length 1 is 1 Character
Содержание PowerScan 9501-AR Series
Страница 32: ...Setup 22 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 36: ...Configuration Using Bar Codes 26 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 92: ...Enter Exit Programming Mode 82 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 184: ...174 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 318: ...References 308 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 322: ...Message Formatting 312 PowerScan PD9531 AR PBT9501 AR PM9501 AR NOTES...
Страница 360: ...Scancode Tables 350 PowerScan PD9531 AR PBT9501 AR PM9501 AR...