![Datalogic MX-U100 Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/datalogic/mx-u100/mx-u100_hardware-manual_3730601056.webp)
Processor Outputs
MX-U Series Hardware Guide
Datalogic Automation, Inc.
4-4
Processor Outputs
The MX-U Series Processors contain sixteen general-purpose current-sink type output connections.
The table below describes the output’s electrical characteristics.
Note
: An external power source is required to power an output load. The outputs are merely switches that are open or
closed. All output connections must use properly grounded and shielded cable.
Note
: The Trigger Signal and Strobe Output for MX-U Series cameras are separate and not part of the MX-U Series Pro-
cessor inputs and outputs. See MX-U Series Cameras on page 3-1 for details.
Supply Voltage
+5 VDC (minimum) to +35 VDC (maximum)
Source Current
(maximum)
100 Milliamperes per output