U1xx Camera Connection (Alternate)
MX-U Series Processor and Camera Guide
Datalogic Automation, Inc.
3-12
The response times for the strobe output on the U1xx camera will typically fall into the ranges specified below. The exact
response time for your application will depend on the external resistor and the applied voltage you use.The shutter begins
opening simultaneously with the “Camera Strobe Output” in the diagram.
Camera Setup and Calibration
Use the Impact programs to setup and calibrate cameras with a MX-U Series processor. (Refer to the Camera Setup Tab
section of the Impact Software Reference Guide.)
Calibration insures that measurements shown in Impact software tools accurately indicate the inspected object's measure-
ments. A camera requires calibration when it is first connected to the MX-U Series Processor, when the camera-to-subject
distance changes, and when the lens is changed. Calibration targets with 0.5, 1.0, and 2.0 mm dot pitches are available
from us (Part number 381-1177). Contact us for printed versions of targets with larger pitches.
Time Delay Rise (TDR) = 40 us
Rise Time (RT) = 20 us to 70 us
Time Delay Fall (TDF) = 0.6 us
Fall Time (FT) = 0.7 us to 1.4 us
Содержание MX-U Series
Страница 1: ...MX U Series Processor and Camera Guide Publication Number 821003220 ...
Страница 4: ......
Страница 6: ...Table of Contents MX U Series Processor and Camera Guide TOC 2 Datalogic Automation Inc U1xx 5 3 ...
Страница 24: ...HASP Key MX U Series Processor and Camera Guide Datalogic Automation Inc 2 8 ...
Страница 50: ...General Purpose Output Circuit Sinking MX U Series Processor and Camera Guide Datalogic Automation Inc 4 6 ...
Страница 54: ...U1xx MX U Series Processor and Camera Guide Datalogic Automation Inc 5 4 ...